Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

نویسندگان

  • Grace J Gang
  • Junghoon Lee
  • J Webster Stayman
  • Daniel J Tward
  • W Zbijewski
  • Jerry L Prince
  • Jeffrey H Siewerdsen
چکیده

PURPOSE Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthesis and cone-beam CT (CBCT) and investigates the extent to which d' is a valid descriptor of task-based imaging performance as assessed by human observers, METHODS The detectability index for tasks presented in 2D slices (d'(slice)) was derived from 3D cascaded systems analysis of tomosynthesis and CBCT. Anatomical background noise measured in a physical phantom presenting power-law spectral density was incorporated in the "generalized" noise-equivalent quanta. Theoretical calculations of d'(slice) were performed as a function of total angular extent (theta(tot)) of source-detector orbit ranging 10 degrees - 360 degrees under two acquisition schemes: (i) Constant angular separation between projections (constant-delta theta), giving variable number of projections (N(proj)) and dose vs theta(tot) and (ii) constant number of projections (constant-N(proj)), giving constant dose (but variable angular sampling) with theta(tot). Five simple observer models were investigated: Prewhitening (PW), prewhitening with eye filter and internal noise (PWEi), nonprewhitening (NPW), nonprewhitening with eye filter (NPWE), and nonprewhitening with eye filter and internal noise (NPWEi). Human observer performance was measured in 9AFC tests for five simple imaging tasks presented within uniform and power-law clutter backgrounds. Measurements (from 9AFC tests) and theoretical calculations (from cascaded systems analysis of d'(slice)) were compared in terms of area under the ROC curve (A(z)) RESULTS Reasonable correspondence between theoretical calculations and human observer performance was achieved for all imaging tasks over the broad range of experimental conditions and acquisition schemes. The PW and PWEi observer models tended to overestimate detectability, while the various NPW models predicted observer performance fairly well, with NPWEi giving the best overall agreement. Detectability was shown to increase with theta(tot) due to the reduction of out-of-plane clutter, reaching a plateau after a particular theta(tot) that depended on the imaging task. Depending on the acquisition scheme, however (i.e., constant-N(proj) or delta theta), detectability was seen in some cases to decline at higher theta(tot) due to tradeoffs among quantum noise, background clutter, and view sampling. CONCLUSIONS Generalized detectability index derived from a 3D cascaded systems model shows reasonable correspondence with human observer performance over a fairly broad range of imaging tasks and conditions, although discrepancies were observed in cases relating to orbits intermediate to 180 degrees and 360 degrees. The basic correspondence of theoretical and measured performance supports the application of such a theoretical framework for system design and optimization of tomosynthesis and CBCT.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Generalized NEQ and Detectability Index for Tomosynthesis and Cone-Beam CT: From Cascaded Systems Analysis to Human Observers.

PURPOSE In the early development of new imaging modalities - such as tomosynthesis and cone-beam CT (CBCT) - an accurate predictive model for imaging performance is particularly valuable in identifying the physical factors that govern image quality and guiding system optimization. In this work, a task-based cascaded systems model for detectability index is proposed that describes not only the s...

متن کامل

Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

PURPOSE Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background "noise" in cascaded systems analysis of 2D and 3D imaging performance to yield "generalized" metrics of noise-equivalent quanta (NEQ) and detectability index as a...

متن کامل

Human and model observer performance for lesion detection in breast cone beam CT images with the FDK reconstruction

We investigate the detectability of breast cone beam computed tomography images using human and model observers and the variations of exponent, β, of the inverse power-law spectrum for various reconstruction filters and interpolation methods in the Feldkamp-Davis-Kress (FDK) reconstruction. Using computer simulation, a breast volume with a 50% volume glandular fraction and a 2mm diameter lesion...

متن کامل

Task-Based Regularization Design for Detection of Intracranial Hemorrhage in Cone-Beam CT.

Prompt and reliable detection of acute intracranial hemorrhage (ICH) is critical to treatment of a number of neurological disorders. Cone-beam CT (CBCT) systems are potentially suitable for detecting ICH (contrast 40-80 HU, size down to 1 mm) at the point of care but face major challenges in image quality requirements. Statistical reconstruction demonstrates improved noise-resolution tradeoffs ...

متن کامل

Soft-tissue detectability in cone-beam CT: evaluation by 2AFC tests in relation to physical performance metrics.

Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal planes, and the effect of prior knowledge on detectability. Custom-built phanto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 2011