A Retrospective Review on Feasibility and Safety of a New Pneumatic Compression Device for Femoral Arteriotomy Hemostasis

نویسندگان

  • Minho Kang
  • Sung Wook Shin
چکیده

OBJECTIVE To report our initial experience on the technical feasibility and safety for hemostasis of a new pneumatic compression device in patients undergoing femoral arteriotomy. MATERIALS AND METHODS This study included 40 consecutive patients in whom hemostasis after transfemoral catheterization was readered by using a pneumatic compression device consisting of an inflatable bulb-containing main body and four pieces of supplementary tape. Medical records were retrospectively reviewed for outcomes and complications of hemostasis. Technical success was defined as achieving immediate hemostasis 10 minutes after applying the device over the arteriotomy sites, and clinical success was defined as the ability to ambulate after 4 hours of bed rest without any complications. RESULTS Technical and clinical success was achieved in 38 (95%) and 37 (93%) patients, respectively. In two patients, hemostasis was achieved after conversion to manual compression. One patient required sand bag placement after removal of the device to control minimal oozing of blood. No patients had late complications. CONCLUSION The new pneumatic compression device provides effective and safe hemostasis after transfemoral catheterization in selected patient populations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemostasis After Brachial Artery Access With the MynxGrip Device: A Case Report

Purpose Brachial access is occasionally used for endovascular procedures when other more established or safer ones (eg, femoral or radial) are contraindicated. Although manual compression is the standard of care after brachial arteriotomy, suboptimal compression may lead to bleeding or thrombosis. Arteriotomy closure devices have thus been proposed as an alternative means to achieve hemostasis ...

متن کامل

Usefulness and safety of the "God's Hand" pneumatic compression device for hemostasis in femoral catheterization.

PURPOSE We aimed to assess the usefulness and safety of the God's Hand pneumatic compression device for hemostasis in patients undergoing percutaneous endovascular procedures via femoral artery. METHODS Two hundred thirty-seven patients in whom hemostasis of femoral catheterization was achieved using a God's Hand pneumatic compression device were enrolled. The patients were divided into group...

متن کامل

Complications of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure: a case-controlled study.

PURPOSE To evaluate the incidence and types of complications encountered with use of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure in a retrospective case-controlled study. MATERIALS AND METHODS The authors identified 100 consecutive patients, 15 men and 85 women 21-85 years of age (mean, 50 years), between December 2000 and July 2001 in whom ...

متن کامل

Pressure ulcer: an unreported complication of the Safeguard® hemostasis device. No need to crack under pressure

Diagnostic cardiac catheterizations are predominantly performed using the femoral artery access. Several devices have been developed to aid in the closure of femoral arteriotomy.Safeguard® is a new pneumatic compression device that has been developed for compression of the femoral artery after brief manual compression. We hereby report the case of an elderly patient who underwent a percutaneous...

متن کامل

Efficacy and safety of a new hemostatic wound dressing following diagnostic heart catheterization

Inadequate hemostasis and bleeding are frequent complications after surgical procedures and medical interventions (for example, after a percutaneous heart catheterization). To stop bleeding during coronary interventions, in addition to mechanical arteriotomy closure devices, many products are used that aid manual compression and/or activate the coagulation cascade. The goal of this study was to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -