Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy.
نویسندگان
چکیده
OBJECTIVES The authors sought to investigate the accuracy of transthoracic echocardiography (TTE)-derived parameters in the identification of bileaflet aortic prosthesis dysfunction, compared with fluoroscopy (FL). BACKGROUND Identification of bileaflet aortic prosthesis dysfunction is challenging, because high mean pressure gradient (MPG >20 mm Hg) is not proof of prosthetic obstruction (AVPO), and may be due to prosthesis-patient mismatch (PPM). Conversely, high gradients may not be manifest in AVPO and low cardiac output. METHODS TTE and FL were prospectively performed in 100 nonconsecutive patients with bileaflet aortic prosthesis. TTE included the estimation of MPG, indexed effective orifice area (EOAi), Doppler velocity index (DVI), intraprosthetic regurgitation, acceleration time (AT), ejection time (ET), AT/ET, and the difference (dA) between the expected prosthetic orifice area and EOA. FL allowed the calculation of opening and closing angles, and the discrimination of AVPO from normal (NL) and PPM. RESULTS On the basis of FL examination and MPG and EOAi at TTE, patients were classified as NL (42%), PPM (32%), and AVPO (26%). High MPG (>20 mm Hg) was present in 65% of the patients, with higher values in PPM (36 ± 8 mm Hg) and AVPO (43 ± 16 mm Hg) than in NL (16 ± 6 mm Hg). DVI was reduced in PPM (0.30 ± 0.05) and AVPO (0.25 ± 0.04) compared with NL (0.42 ± 0.09). In AVPO, dA (0.59 ± 0.32 cm(2)), AT (108 ± 20 ms), and AT/ET (0.35 ± 0.05) significantly differed from NL (dA = -0.12 ± 0.43 cm(2), AT = 74 ± 15 ms, AT/ET = 0.25 ± 0.05) and PPM (dA = 0.15 ± 0.24 cm(2), AT = 78 ± 13 ms, AT/ET = 0.26 ± 0.04). Moderate or severe intraprosthetic regurgitation was observed only in AVPO. All considered TTE-derived parameters were found related to obstruction, and dA (accuracy = 87%), AT (94%), and AT/ET (89%) showed the highest accuracy in discriminating normofunctioning prostheses from AVPO. CONCLUSIONS In the presence of high MPG, TTE parameters play a key role in aortic prosthesis examination. Especially time indices and dA add to the functional assessment of prosthetic aortic valves. However, the TTE discrimination between AVPO and PPM may be suboptimal, and fluoroscopy is a complementary and essential diagnostic step.
منابع مشابه
Huge pannus formation on a mechanical bileaflet mitral valve prosthesis 23 years after a third operation on the mitral valve.
Supplementary material (Videos 1 and 2) is available at EJCTS online. Video 1: Transoesophageal echocardiography showing a blockade of one of the leaflets of the mitral valve prosthesis due to a giant pannus formation with a resulting stenosis and insufficiency. Video 2: Fluoroscopy of aortic valve (top) and mitral valve (bottom) prostheses. There is an almost normal motion amplitude of one lea...
متن کاملAn acute myocardial infarction due to Brucella prosthetic valve endocarditis starting shortly after the onset of non-specific symptoms.
To cite: Aktürk S, Kaya H, Aktürk E. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014209001 DESCRIPTION Brucellosis most commonly causes fever, drenching night sweats and musculoskeletal symptoms, but in 1–2% of cases, it becomes complicated with endocarditis, which accounts for most of the mortality. 2 Brucella prosthetic valve endocarditis (PVE) is a rare en...
متن کاملA bileaflet CarboMedics aortic valve prosthesis with a new unusual "linear" central regurgitant jet: a sign of subtle incomplete closure of one leaflet?
Figure 1. Parasternal imaging in diastole. A. Long-axis image—a prosthetic valvular color jet directed toward the interventricular septum (arrow). (LA = left atrium; LV = left ventricle). B. Short-axis image—the diastolic jet appears to be “central valvular” and “linear” in shape (arrow). (RVOT = right ventricular outflow tract). A 76-year-old retired physician underwent routine follow-up echoc...
متن کاملArtificial aortic valve dysfunction due to pannus and thrombus – different methods of cardiac surgical management
INTRODUCTION Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic com...
متن کاملReplacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.
A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 6 2 شماره
صفحات -
تاریخ انتشار 2013