Benefit of cardiac N-13 PET CFR for combined anatomical and functional diagnosis of ischemic coronary artery disease: a pilot study.
نویسندگان
چکیده
BACKGROUND Cardiac positron emission tomography (PET) can lead to flow impairment quantification using PET coronary flow reserve (CFRp: ratio of stress flow to rest flow) and is superior to the current standard, single-photon emission computed tomography. In this study, our first aim was to assess the benefit of CFRp in place of invasive CFR (CFRi) by comparing the correlations of each of the indices with combined pressure and flow index CDP, and combined functional (pressure-flow) and anatomical (%area stenosis, %AS) index, LFC. The second aim was to test the correlation between CFRp and CFRi. METHODS N-13 ammonia PET scans were performed and CFRp was obtained using a 1-compartment 2K-dynamic volume (DV)-constant kinetic model in Flowquant. During catheterization, simultaneous pressure and flow readings were obtained in 10 vessels (three vessels in one patient, one vessel each in 7 patients) using a dual sensor tipped Combowire, and CFRi, CDP, LFC, and FFR were computed. %AS was obtained using quantitative coronary angiography. CDP was correlated with invasive pressure index (FFR) and CFRp and with FFR and CFRi. LFC was correlated with the %AS, FFR, and CFRp/CFRi, individually and in combination. Correlation analysis was done in SAS; p < 0.05 was used for statistical significance. RESULTS The correlations between CDP vs FFR and CFRp (r = 0.62, p = 0.19) in combination, as well as CDP vs FFR and CFRi in combination (r = 0.58, p = 0.24) remained similar. The correlation between LFC vs FFR, CFRp and %AS in combination improved (r = 0.82) with a near-significant p = 0.06, in comparison to the correlation between LFC vs FFR, CFRi and %AS in combination (r = 0.75, p = 0.15). CFRp correlated strongly and significantly (r = 0.82, p = 0.003) with CFRi, and the values were within 11 %. CONCLUSION The novelty of the PET procedure in this study is that the noninvasive CFRp can be used instead of invasive CFRi for the functional diagnosis of CAD. Therefore, a PET scan can reduce procedure time and cost while simplifying the diagnostic protocol for assessing coronary artery disease, thus benefitting both the patients and clinicians.
منابع مشابه
Coronary flow reserve estimated by positron emission tomography to diagnose significant coronary artery disease and predict cardiac events.
Coronary artery disease (CAD) is a major cause of death in Japan. Coronary angiography is useful to assess the atherosclerotic burden in CAD patients, but its ability to predict whether patients will respond favorably to optimal medical therapy and revascularization is limited. The measurement of the fractional flow reserve with angiography is a well-validated method for identifying ischemic ve...
متن کاملEffects of Eight Weeks of Cardiac Rehabilitation Training on Serum Levels of Sirtuin1 and Functional Capacity of Post- Coronary Artery Bypass Grafting Patients
ABSTRACT Background and Objectives: Cardiac rehabilitation improves functional capacity of post-coronary artery bypass grafting (CABG) patients. Therefore, the aim of this study was to evaluate effects of eight weeks of cardiac rehabilitation on serum levels of sirutin1 (SIRT1) and functional capacity of post-CABG patients. Methods: Forty-five non-active men (mean ag...
متن کاملA Case Report for Ischemic Heart Disease Treatment in a 53-Year-Old Man Based on Iranian Integrative Medicine in Bojnurd
Background: Coronary artery disease is one of the most common causes of death in the world. Despite significant advances in the diagnosis and treatment of these diseases, they are still considered a major health problem in the world. The purpose of this report is to provide the clinical experience of Iranian Integrative Medicine, which has the greatest therapeutic effect in the...
متن کاملApplication of Anatomical and Functional Modalities in Detection of Silent Myocardial Ischemia in Asymptomatic Diabetic Patients- A Review Article
Cardiovascular disease (CAD) screening in asymptomatic patients with diabetes mellitus is controversial. An exercise stress test is a safe and effective initial testing for Ischemic Heart Disease (IHD) screening. Treadmill stress test is not the best screening method for a particular patient who is not able to exercise, abnormal electrocardiogram (ECG) or positive exercise treadmill test (ETT) ...
متن کاملEffect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET
Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 28 8 شماره
صفحات -
تاریخ انتشار 2014