Effect of different air-drying time on the microleakage of single-step self-etch adhesives
نویسندگان
چکیده
OBJECTIVES This study evaluated the effect of three different air-drying times on microleakage of three self-etch adhesive systems. MATERIALS AND METHODS Class I cavities were prepared for 108 extracted sound human premolars. The teeth were divided into three main groups based on three different adhesives: Opti Bond All in One (OBAO), Clearfil S(3) Bond (CSB), Bond Force (BF). Each main group divided into three subgroups regarding the air-drying time: without application of air stream, following the manufacturer's instruction, for 10 sec more than manufacturer's instruction. After completion of restorations, specimens were thermocycled and then connected to a fluid filtration system to evaluate microleakage. The data were statistically analyzed using two-way ANOVA and Tukey-test (α = 0.05). RESULTS The microleakage of all adhesives decreased when the air-drying time increased from 0 sec to manufacturer's instruction (p < 0.001). The microleakage of BF reached its lowest values after increasing the drying time to 10 sec more than the manufacturer's instruction (p < 0.001). Microleakage of OBAO and CSB was significantly lower compared to BF in all three drying time (p < 0.001). CONCLUSIONS Increasing in air-drying time of adhesive layer in one-step self-etch adhesives caused reduction of microleakage, but the amount of this reduction may be dependent on the adhesive components of self-etch adhesives.
منابع مشابه
Effect of warm air-drying on dentin bond strength of single-step self-etch adhesives.
The effect of warm air-drying on the dentin bond strengths of the single-step self-etch adhesives was determined. The adhesives were applied to bovine dentin followed by drying in a stream of warm air for 5, 10, and 15 s at 37°C. Resin composites were condensed into a mold and polymerized. Specimens were stored in distilled water at 37°C for 24 h, then shear tested. The surface free-energies we...
متن کاملمقایسه میزان تبخیر حلال در ادهزیوهای سلفاچ و توتالاچ در زمانهای مختلف خشک کردن با هوا
Background and Aims: Different adhesives with different solvents may have different solvent evaporation rates. The purpose of this study was to evaluate the solvent evaporation in the self etch and total etch adhesive in different air drying times. Materials and Methods: Five adhesives were used in this study: Excite, Prime & Bond NT, UNO, Single Bond, SE Bond Primer. Twelve drops of each a...
متن کاملبررسی اثر زمان و دمای تبخیر حلال دو نوع ادهزیوتوتال اچ بر استحکام باند ریزکششی کامپوزیت به عاج
Introduction: Effect of drying time and temperature of solvent evaporation were different in different studies. Therefore, the aim of this study was to investigate the appropriate drying temperature and time of solvent evaporation in the two adhesives of Etch and Rinse. Methods: Seventy-two sound third molars were collected. On the buccal surface of the crown, flat dentinal surfaces were crea...
متن کاملMicroleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations
Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations. Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...
متن کاملMicroleakage assessment of one- and two-step self-etch adhesive systems with the low shrinkage composites
BACKGROUND AND AIM: Different studies evaluating one-step self-etch (SE) adhesive systems show contradictory findings, so the aim of this study was to compare the microleakage of one-step SE adhesive systems and CLEARFIL SE BOND (that serves as the “gold-standard” SE adhesive) with low shrinkage composites. METHODS: In this in vitro study, Class V cavities with the occlusal margin in enamel and...
متن کامل