A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr - Oliver nylon cyclones operated - 1 at 1 . 7 and 2 . 0
نویسندگان
چکیده
Accurate measurement of workplace respirable dust concentration is an essential step in eliminating lung disease in any occupational setting. In the United States (U.S.) coal mining industry, this measurement process has relied upon a personal sampler that includes a 10 mm Dorr-Oliver (DO) nylon cyclone operated at a flow rate of 2.0 L min-1 to collect a respirable dust sample. Dust concentrations measured with this sampler are multiplied by 1.38, which was empirically derived, to convert them to measurements approximating the United Kingdom British Medical Research Council (BMRC) definition of respirable dust upon which the health effects of coal mine dust are based. The International Organization for Standardization (ISO) subsequently refined the respirable dust definition and the U.S. National Institute for Occupational Safety and Health (NIOSH) 1995 Criteria for a Recommended Standard presented a conversion multiplier of 0.857 to apply to the 2.0 L min-1 DO (in addition to the1.38 multiplier) to obtain equivalent ISO concentrations, as approximated by the 1.7 L min-1 DO. However, the conversion multiplier 0.857 was derived indirectly from a limited size distribution data set rather than a direct comparison of the DO samplers. The present analysis focuses on providing a more accurate conversion multiplier derived from direct comparisons of the 2.0 L min-1 (with 1.38 BMRC equivalency multiplier) and 1.7 L min-1 DO cyclones. A weighted linear regression analysis of this database suggests that a more accurate estimate of the conversion multiplier is 0.815.
منابع مشابه
Evaluation of pump pulsation in respirable size-selective sampling: part I. Pulsation measurements.
Pulsations generated by personal sampling pumps modulate the airflow through the sampling trains, thereby varying sampling efficiencies, and possibly invalidating collection or monitoring. The purpose of this study was to characterize pulsations generated by personal sampling pumps relative to a nominal flow rate at the inlet of different respirable cyclones. Experiments were conducted using a ...
متن کاملEquivalency of a personal dust monitor to the current United States coal mine respirable dust sampler.
The United States National Institute for Occupational Safety and Health, through an informal partnership with industry, labor, and the United States Mine Safety and Health Administration, has developed and tested a new instrument known as the Personal Dust Monitor (PDM). The new dust monitor is an integral part of the cap lamp that coal miners normally carry to work and provides continuous info...
متن کاملPerformance of High Flow Rate Samplers for Respirable Particle Collection
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(-3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative...
متن کاملارزیابی مواجهه شغلی کارکنان یک کارخانه تولید سیمان با گرد و غبار قابل استنشاق سیمان و سیلیس کریستالی
Introduction: Exposure to respirable fraction of cement dust and its crystalline silica content is the most important occupational risk factor in cement industries requiring more evaluation and monitoring. This study aimed to assess exposure to crystalline silica and cement dust among workers of a cement industry in Saveh city, Iran. . Material and Method: In this cross-sectional study, 62 s...
متن کاملMeasurements of respirable dust and nanoparticle concentrations in a titanium dioxide pigment production factory.
This study compared respirable dust and nanoparticle concentrations measured by different sampling devices at a titanium dioxide pigment factory. Respirable particle mass concentrations, nanoparticle concentrations, particle size distribution and particle metallic content were measured at different sampling locations. The sampling results of the Multi-orifice Uniform Deposit Impactor (MOUDI) sh...
متن کامل