Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms.

نویسندگان

  • K Kono
  • T Terada
چکیده

BACKGROUND AND PURPOSE SACE is performed for complex aneurysms. There are several configurations of stent placement for bifurcation aneurysms. We investigated hemodynamics among 8 different configurations of stent placement, which may relate to the recanalization rate. MATERIALS AND METHODS We created a silicone block model of a patient-specific asymmetric bifurcation aneurysm. Enterprise closed-cell stents were deployed in the model as various configurations. 3D images of these stents were obtained by micro-CT. We performed CFD simulations for a no-stent model and 8 stent models: a single stent from a proximal vessel to a right or left distal vessel, a horizontal stent, a kissing-Y stent with a uniformly narrowed structure, a nonoverlapping-Y stent, a virtual-Y stent with no narrowed structure (fusion of 2 single stents), and 2 different crossing-Y stents with a focally narrowed structure. Hemodynamic parameters were evaluated. RESULTS Cycle-averaged velocity and WSS in the aneurysm were reduced because of stent placement in the following order: single stent (19% reduction in cycle-averaged velocity) < nonoverlapping-Y stent (29%) < virtual-Y stent (32%) < horizontal stent (39%) < kissing-Y stent (48%) < crossing-Y stent (54%). Kissing- and crossing-Y stents redirected impingement flow into the distal vessels because of lowered porosity of stents due to narrowed structures. CONCLUSIONS Among 8 different configurations of stent placement, kissing- and crossing-Y stents showed the strongest reduction in flow velocity in the aneurysm because of lowered porosity of stents and redirection of impingement flow. This may be a desirable reconstruction of flow hemodynamics and may decrease recanalization rates in SACE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Y-Stenting for Bifurcation Aneurysm Coil Embolization: What is the Risk?

The use of two stents in a "Y" configuration (Y-stenting) to assist with coil embolization of complex bifurcation aneurysms has been accepted as an alternative to clip reconstruction of a select subset of challenging aneurysms. We review the risks associated with Y-stenting, including its procedural complication rates, angiographic occlusion rates, rerupture, and retreatment rates.

متن کامل

Morphological Distinguish of Rupture Status between Sidewall and Bifurcation Cerebral Aneurysms Caracterización Morfológica del Estado de Ruptura entre Aneurismas Cerebrales en Paredes Laterales y Bifurcaciones

We suspect that morphological change of two types of aneurysms in ruptured and unruptured aneurysms are distinguishing because of different location and haemodynamics. So it is necessary to discuss sidewall and bifurcation type aneurysms in ruptured and unruptured state respectively. We used 209 consecutive aneurysms (144 ruptured, 65 bifurcation type) to assess the following parameters in 3D: ...

متن کامل

Computational Fluid Dynamics Study of Bifurcation Aneurysms Treated with Pipeline Embolization Device: Side Branch Diameter Study

An intracranial aneurysm, abnormal swelling of the cerebral artery, may lead to undesirable rates of mortality and morbidity upon rupture. Endovascular treatment involves the deployment of a flow-diverting stent that covers the aneurysm orifice, thereby reducing the blood flow into the aneurysm and mitigating the risk of rupture. In this study, computational fluid dynamics analysis is performed...

متن کامل

Infra-Inguinal Aneurysms – Threat to Life and Limb?

Results: 39 patients (mean age 58.3yr, range 18-98), of which 27 were male, were identified (24 PseudoAneurysms (PA), 12 True Aneurysms (TA) and 3 Mycotic Aneurysms (MA)). The majority of the PAs were secondary to Intravenous Drug Abuse, IVDA (41%), followed by interventional procedures (29%), vascular anastomotic sites (13%), orthopaedic surgery (13%) and penetrating trauma (4%). 11/12 (92%) T...

متن کامل

114 Treatment of Bifurcation Aneurysms Using Single Stent-Coiling With Relation to Aneurysm Configuration: A Cohort Study of Two Academic Institutions in the United States.

INTRODUCTION Stent-coiling of bifurcation aneurysms has significantly expanded the spectrum of aneurysms amenable to endovascular therapy. A variety of techniques have evolved to deal with wide-necked bifurcation aneurysms such as Y-stenting and WEB embolization device. In our 2 institutions, we have primarily used a single stent coiling to treat most bifurcation aneurysms. We present a large s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 2013