Scintillator distribution in high-speed autoradiography.

نویسندگان

  • L Goldgefter
  • V Toder
چکیده

Durie and Salmon (1) describe the technique of impregnation ofphotographic emulsion with liquid scintillator which allows rapid autoradiographic labeling. In attempting to use this method, we found that freezing the impregnated slides without special conditions led to the formation of large ice crystals and irregularities in the frozen scintillator. They appeared even when the dioxane did not contain either 2,5-diphenyloxazole or I1,4-bis-2-(4-methyl-5-phenyloxazolyl)-benzene. It could be seen clearly with the ultraviolet lamp (UVSL58, Product Inc., San Gabriel, California). Crystalline pictures of the scintillator luminescence show that molecules of the fluorescent substance are distributed nonhomogeneously over the biological sample. Hence, distorted distribution-of silver grains in developed emulsion layers seems to be inevitable. A crystalline structure can also be seen under light microscopy. In order to circumvent these difficulties, we attempted to obtain uniform coating of the slides with the scintillator by quick deep freezing. The slides were dipped in horizontal position into the precooled isopentane so that the surface ofthe slide containing the biological sample and the impregnated emulsion remained free. Isopentane was cooled by liquid nitrogen. Rapid deep freezing of the scintillator can be obtained also by spraying the substance on the previously frozen slides, as above. Examination with an ultraviolet lamp and light microscope of the slices frozen by described techniques shows that crystals are not formed and fluorescent molecules are distributed in a homogeneous way. We think that the suggested system of rapid freezing can contribute to more correct readings of autoradiograms prepared by the high-speed scintillation autoradiography technique. L. GOLDGEFTER, V. TODER Department ofAnatomy and Anthropology and Department of Embryology and Teratology, Tel Aviv University, Tel Aviv, Israel

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Actinide bioimaging in tissues: Comparison of emulsion and solid track autoradiography techniques with the iQID camera

This work presents a comparison of three autoradiography techniques for imaging biological samples contaminated with actinides: emulsion-based, plastic-based autoradiography and a quantitative digital technique, the iQID camera, based on the numerical analysis of light from a scintillator screen. In radiation toxicology it has been important to develop means of imaging actinide distribution in ...

متن کامل

Time Consumption Modeling of Planning Vertical Profile of High-Speed Railways

Recent years, High-Speed railway has become a hot topic of railway development. Many countries in the world have built relatively complete high-speed railway networks.Each of them enjoys its own efficient traffic organization system and method, as well as a theory of station distribution layout. Based on the railway traffic conditions in China, the designer is adopting special procedure for bu...

متن کامل

Preparation of nanocomposite scintillator of ZnS doped with Ag, Cu and AgCu for alpha particle detection

ZnS nanoparticles (NPs) doped with ‎Ag‎, ‎Cu‎, ‎and AgCu were synthesized using hydrothermal‎ ‎method in water solution‎. ‎The NPS are characterized by X-ray diffraction (XRD)‎, ‎energy-dispersive‎ ‎X-ray spectroscopy scanning (EDX)‎, ‎scanning electron‎ ‎microscopy (SEM) and dynamic light scattering (DLS)‎. ‎The produced NPs have approximately hexagonal structure and a cubic zinc blended struc...

متن کامل

Developing a high-resolution x-ray imager using electron-multiplying (EM) CCDs

Applications at synchrotron facilities such as macromolecular crystallography and high energy X-ray diffraction require high resolution imaging detectors with high dynamic range and large surface area. Current systems can be split into two main categories: hybrid pixel detectors and scintillator-coupled Charge-Coupled Devices (CCDs). Whilst both have limitations, CCD-based systems (coupled to f...

متن کامل

Autoradiography: technique for drastic reduction of exposure time to alpha particles.

High-speed, gross, alpha autoradiographs can be made if silver-activated zinc sulfide is used as an intensifier in conjunction with high-speed film. The intensifier is interposed between the sample and film. This technique requires about 1/1000 of the exposure time required with Kodak NTB plates. The gross autoradiographs have greater contrast but slightly less resolution than conventional plates.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Science

دوره 195 4274  شماره 

صفحات  -

تاریخ انتشار 1977