Evaluation of different LED light-curing devices for bonding metallic orthodontic brackets.
نویسندگان
چکیده
The aim of this study was to assess the influence of different light-emitting diodes (LED) light-curing devices for bonding orthodontic brackets, using the shear bond strength and analysis of adhesive remnant index (ARI). Crowns from 60 bovine incisors received brackets bonded with Transbond XT. Specimens were divided into 4 groups (n=15) according to the light-curing procedures: HL = control, halogen light; OR = Ortholux LED; UL = Ultraled XP, and RD = Radii LED. All light-curing procedures were performed for 40 s. Shear bond strength test was evaluated using an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by ANOVA and Tukey's test. The ARI scores were evaluated with a stereoscopic magnifying glass and analyzed statistically by Kruskal-Wallis test. A significance level of 5% was set for all analyses. Shear bond strength means in MPa and standard deviations were 9.82 (3.28), 12.70 (3.35), 9.04 (2.80) and 11.22 (2.36) for HL, OR, UL and RD, respectively. OR presented the highest shear bond strength mean value. HL differed significantly (p<0.05) from Groups OR and RD. However, these groups did not differ significantly from each other (p>0.05). Regarding the ARI scores, no statistically significant difference was observed (p>0.05) among the groups. In conclusion, Ortholux LED and Radii LED units provided the highest values of bracket adhesive strength.
منابع مشابه
Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth
BACKGROUND Although using light-cured composites for bonding orthodontic brackets has become increasingly popular, curing light cannot penetrate the metallic bulk of brackets and polymerization of composites is limited to the edges. Limited access and poor direct sight may be a problem in the posterior teeth. Meanwhile, effectiveness of the trans-illumination technique is questionable due to in...
متن کاملShear Bond Strength and Temperature Rise of Orthodontic Brackets Bonding by Using a New 3-Second LED Mode
Objective: The aim of this study was to evaluate the effects of different curing times of a light-emitting diode (LED) on the bond strength of stainless steel brackets and to evaluate the temperature changes in the pulp chamber during curing of the composite. Materials and Method: Caries-free human first premolar and maxillary central incisor teeth extracted for orthodontic and periodontal reas...
متن کاملShear Bond Strength of Metallic Brackets Photo-activated with Light-emitting Diode (led) at Different Exposure Times
The purpose of this study was to compare the shear bond strength of orthodontic metallic brackets photo-activated with two different light-curing sources at different exposure times: halogen light (XL 1500, 3M ESPE) and LED light (Ortholux, 3M Unitek). Sixty bovine permanent lower incisors were inserted into PVC tubes containing plaster. The buccal surfaces were cleaned with pumice and water, a...
متن کاملThe effect of the blue light diode laser on shear-peel bond strength of orthodontic brackets with varying curing time and distance
THE EFFECT OF THE BLUE LIGHT DIODE LASER ON SHEAR-PEEL BOND STRENGTH OF ORTHODONTIC BRACKETS WITH VARYING CURING TIME AND DISTANCE Kamran Shaikh, DDS June 17,2010 Background: Light cured composite resin can be time consuming for bonding orthodontic brackets. A new Blue light diode laser may reduce curing times for composite resins. Hypothesis: The laser will achieve similar bond strengths in ha...
متن کاملEffect of Saliva Contamination and sequencing time of curing the Transbond™ Plus Self Etching Primer on the Shear Bond Strength of Orthodontic Brackets
Abstract Background and aim: Over the years, improvments have been done to simplify clinical bonding procedure. One of these material is Transbond™ Plus Self Etching. The aim of this study was to evaluate the effect of saliva contamination and reusing Transbond™ Plus Self Etching Primer (SEP) on shear bond strength of orthodontic brackets. Materials and Methods: Fifty premolars divided into fiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 22 3 شماره
صفحات -
تاریخ انتشار 2011