The effect of intraocular pressure on human and rabbit scleral permeability.
نویسندگان
چکیده
PURPOSE The purpose of this study was to evaluate the effects of intraocular pressure on the permeability of human and rabbit sclera to water, dexamethasone, and carboxyfluorescein. METHODS Scleral sections excised from moist-chamber-stored human globes or eyes obtained from euthanatized New Zealand White rabbits were mounted in a perfusion chamber that can create a transscleral pressure that simulates an intraocular pressure. A small depot of drug (100 microl) was added to the episcleral surface while perfusing an irrigating solution slowly across the choroidal side. The perfusate was collected and scleral permeability calculated. Experiments were performed at 0, 15, 30, and 60 mm Hg for each compound in human and rabbit tissue. RESULTS Analysis of variance showed a significant effect of intraocular pressure on both human and rabbit scleral permeability. Human scleral permeability was decreased by as much as a factor of two for water (P = 0.0004), dexamethasone (P<0.0001), and carboxyfluorescein (P = 0.0064) at elevated intraocular pressures. Rabbit scleral permeability was similarly affected by elevated intraocular pressure for water (P = 0.0039), dexamethasone (P = 0.0001), and carboxyfluorescein (P = 0.0016). CONCLUSIONS This study shows that simulated intraocular pressure ranging from 15 to 60 mm Hg can decrease scleral permeability to small molecules by one half when compared with the sclera with no pressure applied.
منابع مشابه
Passive radiotelemetry of intraocular pressure in vivo: calibration and validation of continual scleral guard-ring applanation transensors in the dog and rabbit.
Continual monitoring of intraocular pressure (IOP) by passive radiotelemetry, with a miniature scleral applanating device, mounted in a haptic contact lens (applanating transensor) is reported in the rabbit and dog. Several prototype transensors were calibrated in vivo in the rabbit and dog; a consistent linear output was obtained for each eye, although reproducibility of the slope between eyes...
متن کاملThe Effect of Altitude on Intraocular Pressure in Vitrectomized Eyes with Sulfur Hexafluoride Tamponade by the Friedenwald Method: Rabbit Animal Model
The aim of this study is to assess the change in intraocular pressure after a road trip, in eyes with different levels of filling with gas tamponade. Five rabbit eyes were subject to pars plana vitrectomy and gas tamponade (filling percentage: 25%, 50%, and 100% of nonexpansile SF6, 100% saline solution, and 100% room air). A sixth eye was injected with 0.35 cc of undiluted SF6 without vitrecto...
متن کاملWhat is the Real Cause of Glaucoma?
Introduction: The term glaucoma refers to a group of diseases that have a characteristic optic neuropathy with associated visual field loss in common. Intraocular pressure has been considered to be the only causal factor for glaucoma and the only factor that can be manipulated to alter the course of the disease. But considering high intraocular pressure as the only factor responsible for glauco...
متن کاملEffect of experimental scleral shortening on axial length of the rabbit eye.
PURPOSE To evaluate the change of axial length (AL), intraocular pressure (IOP), and corneal astigmatism after scleral shortening with scleral invagination in the rabbit eye. METHODS The authors performed scleral shortening (3 mm) with scleral invagination in two groups of 6 eyes each: 180 degrees (group 1) and 360 degrees (group 2). RESULTS Average AL shortening was more prominent in group...
متن کاملDiffusion of high molecular weight compounds through sclera.
PURPOSE To determine the in vitro permeability of the sclera to high molecular weight compounds and the relationship between scleral permeability and molecular size. METHODS Fresh rabbit sclera was mounted in a two-chamber diffusion apparatus, and its permeability to sodium fluorescein, fluorescein isothiocyanate (FITC)-conjugated bovine serum albumin, FITC-IgG, and FITC dextrans ranging in m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 40 12 شماره
صفحات -
تاریخ انتشار 1999