Errors resulting from finite beamwidth and sample dimensions in the determination of the ultrasonic absorption coefficient
نویسنده
چکیده
The error resulting from heat conduction i the measurement ofthe ultrasonic absorption coeffcient using the transient thermoelectric method is studied analytically. An expression for the temperature increase in a tissue specimen of finite dimensions, irradiated by a focused ultrasonic transducer, isgiven as a function of spatial coordinates, time, radial and axial beam dimensions, and absorption. An error is defined, and results are presented for various values of beamwidth, tissue dimensions, absorption, and time for the purpose of quantifying the experimental error due to heat conduction, and to provide guidance for minimizing this error in experimental procedures. For example, it is shown that the effect of heat conduction on the measured rate of temperature increase is less than 7% when using a transducer with a 5-ram half-power beamwidth at depths greater than 1.5 mm in the tissue.
منابع مشابه
Ultrasonic guided waves reflection from simple dent in pipe for defect rate estimation and parameters determination of axisymmetric wave generation source
In this paper, the reflection of ultrasonic guided waves from simple dent in pipes has been investigated using finite element method and the relationship between reflection coefficient of these waves and deformation rate has been determined. Also, the effect of the parameters of wave generation source on the generated wave field has been investigated using normal modes expansion method. At firs...
متن کاملEffects of heat conduction and sample size on ultrasonic absorption measurements.
The absorption coefficient of a material can be determined by measuring the heating which occurs as a result of ultrasonic irradiation. When narrow focused beams are used to heat a sample, or when the available volume of a material is restricted to small dimensions, then the effect of heat conduction to surrounding unheated regions becomes significant, complicating the relation between measured...
متن کاملDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملUltrasonic-Assisted Matrix Solid-Phase Dispersion and High-Performance Liquid Chromatography as an Improved Methodology for Determination of Oleuropein from Olive Leaves
In this study, ultrasonic-assisted matrix solid-phase dispersion (UA-MSPD) as a new sample preparation method for natural product analysis was developed. Influential parameters of the UA-MSPD method was optimized using oleuropein content of olive leaves as a model analyte. Main parameters of the proposed technique such as ultrasonic time, amplitude and pulse, sorbent material, the ratio of samp...
متن کاملتحلیل دینامیکی سدهای بتنی وزنی با مدلسازی مخزن به روشهای لاگرانژی و اویلری
Because of different behavior of reservoir water and dam material, the determination of hydrodynamic pressure during earthquake is very complicated. Thus, different formulations have been presented for modeling of the dam reservoir system under dynamic loading such as earthquake. These formulations can be categorized into two general groups, which are Lagrangian and Eulerian, each having advant...
متن کامل