Modelling of Amperometric Biosensors in the Case of Substrate Inhibition

نویسندگان

  • Juozas Kulys
  • Romas Baronas
چکیده

The response of an amperometric biosensor at mixed enzyme kinetics and diffusion limitations was modelled digitally in the case of substrate inhibition. Digital simulations were carried out using a finite difference technique. Calculations showed complex kinetics of biosensor response. At low enzyme activity and substrate concentration (S0), the response of the sensor looks like it is limited by a simple substrate diffusion. At substrate concentration comparable to the Michaelis-Menten constant (KM), the response change shows a maximal value. A sharp response change was indicated at high enzyme activity and high (4.9 > S0/KM > 4.5) substrate concentration. This was explained by multiconcentration of substrate generation inside the enzyme layer. This conclusion was confirmed by the analytical solution of the simplified biosensor model with external diffusion limitation at steady-state conditions. The complex kinetics of response change produces different calibration graphs for biosensor response at transition and steady state.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes

The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...

متن کامل

Modelling Amperometric Biosensors Based on Chemically Modified Electrodes

The response of an amperometric biosensor based on a chemically modified electrode was modelled numerically. A mathematical model of the biosensor is based on a system of non-linear reaction-diffusion equations. The modelling biosensor comprises two compartments: an enzyme layer and an outer diffusion layer. In order to define the main governing parameters the corresponding dimensionless mathem...

متن کامل

Label-free electrochemical biosensors for food and drug application

In food sector, there is a huge demand for rapid, reliable, user & eco-friendly biosensors to analyse the quality and safety of food products. Biosensor based methodology depends upon the recognition of a specific antigens or receptors by corresponding antibodies, aptamers or high-affinity ligands. The first scientifically commercialised sensors were the electrochemical sensors used for the ana...

متن کامل

Label-free electrochemical biosensors for food and drug application

In food sector, there is a huge demand for rapid, reliable, user & eco-friendly biosensors to analyse the quality and safety of food products. Biosensor based methodology depends upon the recognition of a specific antigens or receptors by corresponding antibodies, aptamers or high-affinity ligands. The first scientifically commercialised sensors were the electrochemical sensors used for the ana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006