Improved Slice Profile and Reduced Fast Spin Echo Spacing with Variable-Rate Selective Excitation

نویسندگان

  • R. F. Busse
  • B. S. Li
  • X. Li
چکیده

The Variable-Rate Selective Excitation (VERSE) technique is shown to improve image quality by reducing fast spin echo spacing and improving slice profile. An algorithm was developed to use VERSE waveform reshaping to minimize echo spacing given specific prescription parameters and system constraints and was implemented for an SSFSE sequence to create shorter RF pulses with higher time•bandwidth products. Phantom and volunteer experiments demonstrate reduced crosstalk, and increased resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verse - Space

Introduction Use of nonselective refocusing pulses shortens the echo spacing and the echo train duration, and then improves the image sharpness in SPACE [3, 4] imaging. However, the nonselective refocusing pulses limit the application of slab selective acquisition. To overcome this limitation, a dual echo-spacing technique [1] has been presented before, using a combination of selective excitati...

متن کامل

A simple low-SAR technique for chemical-shift selection with high-field spin-echo imaging.

We have discovered a simple and highly robust method for removal of chemical shift artifact in spin-echo MR images, which simultaneously decreases the radiofrequency power deposition (specific absorption rate). The method is demonstrated in spin-echo echo-planar imaging brain images acquired at 7 T, with complete suppression of scalp fat signal. When excitation and refocusing pulses are suffici...

متن کامل

Hadamard slice encoding for reduced-FOV diffusion-weighted imaging.

PURPOSE To improve the clinical utility of diffusion-weighted imaging (DWI) by extending the slice coverage of a high-resolution reduced field-of-view technique. THEORY Challenges in achieving high spatial resolution restrict the use of DWI in assessment of small structures such as the spinal cord. A reduced field-of-view method with 2D echo-planar radiofrequency (RF) excitation was recently ...

متن کامل

A Novel Non-contrast MR Angiography Technique using Triggered Non-Selective Refocused SPACE for Improved Spatial Resolution and Speed

Introduction: A non-contrast-enhanced MRA technique using gated 3D Turbo Spin Echo (TSE) has been reported for various clinical applications [1] [2], whereby systolic images are subtracted from diastolic images to provide high resolution MRA without exogenous contrast agents. Half-Fourier single-shot TSE results in a relatively long readout duration which causes vessel blurring due to T2 filtra...

متن کامل

Fresh Blood Imaging using variable TR and variable refocusing flip angle for non-contrast peripheral MR angiography at 3T: a 7-Minute iliac to calf station run-offs scan

Background Non-contrast Fresh Blood Imaging (FBI) scan time can be greatly reduced using variable TR for imaging the peripheral artery without contrast infusion, in which each slice encoding (SE) and the followed echo train are played in a variable TR (vTR) (TR=n*RR) pattern. In vTR FBI, the lower limit of TR depends on the length and timing of data acquisition, and it is also limited by SAR, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002