Design Of High Energy-Efficiency Air Conditioner With Asymmetric Fin Condenser Tube
نویسندگان
چکیده
This paper presents the detailed design and analysis of an asymmetric fin tube condenser. And the heat transfer performance of the asymmetric fin tube condenser is simulated with the fluent software. Based on the simulation results, an optimal model of the asymmetric-finned tube condenser is designed. The actual model is experimentally studied on air conditioners and contrasted with the symmetric-finned tube condenser under the same conditions. The experimental results show that the overall power is decreased 1.7%, the refrigerant capacity is increased as 1% and the energy efficiency ratio is enhanced 2.6%. The good actual effects provided a new way to obtain high energy-efficient of air conditioner.
منابع مشابه
Design and Experimentation of Roll Bond Evaporator for Room Air Conditioner with R-22 as Refrigerant
The world is looking towards producing products which consume less power without compromising on quality of life. The increase in use of refrigeration and air conditioning appliances are contributing to global warming. The world wide temperatures are shooting up at an increasing rate. This paper presents a design of roll bond evaporator as the heat exchanger to provide cooling in room air condi...
متن کاملRequest for Admission to Ph
Name: S u s a n W. S t e w a r t Brief Description: The HCFC refrigerant, R-22, is the most widely used residential air-conditioner refrigerant in the U.S. However, it is scheduled to be banned in new equipment beginning in 2010 due to its high ozone depletion potential (ODP). A new refrigerant, R-410A has zero ODP and favorable performance characteristics such as good cycle efficiency, non-fla...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملStudy and Optimization of Performance Parameters of Air- Conditioner by Using Waste Water of Water-Cooler
Reduction of energy consumption and rise of cooling is a major concern in the air conditioning system especially in the area with very hot weather conditions. In hot weather conditions, the air conditioner takes more electrical power consumption to bring the comfort in specified area. In many Middle East countries, the atmospheric temperature approaches 40°C to 50°C or sometimes higher. During ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Intelligent Automation & Soft Computing
دوره 18 شماره
صفحات -
تاریخ انتشار 2012