Rheothermodynamics of transient networks

نویسنده

  • Jean-François Palierne
چکیده

Synopsis : The transient network model of Green-Tobolsky [1946], Yamamoto [1956] and Tanaka-Edwards [1992] is formulated within the frame of thermodynamics of irreversible processes, using as a fundamental quantity the chemical potential associated to the connection of strands to the network and treating these connections as chemical-like reactions. All thermodynamic quantities are thus naturally defined in and out of equilibrium. Constitutive equations are derived, giving the stress and the heat production as functions of the thermomechanical history. The Clausius-Duhem inequality, stating that the source of entropy is non-negative, is shown to hold for any thermomechanical history, ensuring the thermodynamic consistency of our model. The presented model includes the Green-Tobolsky model, whereas those of Yamamoto and Tanaka-Edwards fit within ours on the condition that their free parameters obey a detailed balance condition stemming form Boltzmann equilibrium statistics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Measurement Site Design in pipe networks using the Decision Table Method (DTM)

The accuracy of leak detection and calibration of pipe networks by means of the inverse transient analysis (ITA) is highly affected by the number and location of the measurement sites. This study introduces a conceptual decision-making model, the Decision Table Method (DTM), for the measurement site design of pipe networks with the aim of inverse transient analysis. Through the Decision Table M...

متن کامل

Fast Transient Hybrid Neuro Fuzzy Controller for STATCOM During Unbalanced Voltage Sags

A static synchronous compensator (STATCOM) is generally used to regulate voltage and improve transient stability in transmission and distribution networks. This is achieved by controlling reactive power exchange between STATCOM and the grid. Unbalanced sags are the most common type of voltage sags in distribution networks. A static synchronous compensator (STATCOM) is generally used to maintain...

متن کامل

Cross Entropy-Based High-Impedance Fault Detection Algorithm for Distribution Networks

The low fault current of high-impedance faults (HIFs) is one of the main challenges for the protection of distribution networks. The inability of conventional overcurrent relays in detecting these faults results in electric arc continuity that it causes the fire hazard and electric shock and poses a serious threat to human life and network equipment. This paper presents ​an HIF detection algori...

متن کامل

Spike timing dependent plasticity: mechanisms, significance, and controversies

Long-term modification of synaptic strength is one of the basic mechanisms of memory formation and activity-dependent refinement of neural circuits. This idea was purposed by Hebb to provide a basis for the formation of a cell assembly. Repetitive correlated activity of pre-synaptic and post-synaptic neurons can induce long-lasting synaptic strength modification, the direction and extent of whi...

متن کامل

A New Algorithm for Load Flow Analysis in Autonomous Networks

In this paper, a novel algorithm for the load flow analysis problem in an islanded microgrid is proposed. The problem is modeled without any slack bus by considering the steady state frequency as one of the load flow variables. To model different control modes of DGs, such as droop, PV and PQ, in an islanded microgrid, a new formula for load flow equations is proposed. A hybrid optimization alg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000