ORIGINAL COMMUNICATION Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water
نویسندگان
چکیده
Objective: To establish the accuracy of an eight-polar tactile-electrode impedance method in the assessment of total body water (TBW). Design: Transversal study. Setting: University department. Subjects: Fifty healthy subjects (25 men and 25 women) with a mean (s.d.) age of 40 (12) y. Methods: TBW measured by deuterium oxide dilution; resistance (R) of arms, trunk and legs measured at frequencies of 5, 50, 250 and 500 kHz with an eight-polar tactile-electrode impedance-meter (InBody 3.0, Biospace, Seoul, Korea). Results: An algorithm for the prediction of TBW from the whole-body resistance index at 500 kHz (height =R500 where R is the sum of the segmental resistances of arms, trunk and legs) was developed in a randomly chosen subsample of 35 subjects. This algorithm had an adjusted coefficient of determination (radj) of 0.81 (P< 0.0001) and a root mean square error (RMSE) of 3.6 l (9%). Cross-validation of the predictive algorithm in the remaining 15 subjects gave an radj of 0.87 (P<0.0001) and an RMSE of 3.0 l (8%). The precision of eight-polar BIA, determined by measuring R three times a day for five consecutive days in a fasting subject, was 2.8% for all segments and frequencies. Conclusion: Eight-polar BIA is a precise method that offers accurate estimates of TBW in healthy subjects. This promising method should undergo further studies of precision and its accuracy in assessing extracellular water and appendicular body composition should be determined. Sponsorship: Modena and Reggio Emilia University. European Journal of Clinical Nutrition (2002) 56, 1143 – 1148. doi:10.1038=sj.ejcn.1601466
منابع مشابه
J Physiol Anthropol Appl Human Sci 23 (3): 93–99, 2004
The present study aimed to compare the accuracy of estimating the percentage of total body fat (%TBF) among three bioelectrical impedance analysis (BIA) devices: a singlefrequency BIA with four tactile electrodes (SF-BIA4), a single-frequency BIA with eight tactile electrodes (SF-BIA8) and a multi-frequency BIA with eight tactile electrodes (MFBIA8). Dual-energy x-ray absorptiometry (DXA) and h...
متن کاملExternal cross-validation of bioelectrical impedance analysis for the assessment of body composition in Korean adults
Bioelectrical impedance analysis (BIA) models must be validated against a reference method in a representative population sample before they can be accepted as accurate and applicable. The purpose of this study was to compare the eight-electrode BIA method with DEXA as a reference method in the assessment of body composition in Korean adults and to investigate the predictive accuracy and applic...
متن کاملComparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis
Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...
متن کاملAssessment of total body water using bioelectrical impedance analysis in neonates receiving intensive care.
AIMS To determine the most suitable anthropometric and impedance measures and current frequency for the application of bioelectrical impedance to neonates receiving intensive care; and to derive predictive models for the estimation of total body water. METHODS Twenty eight babies (median gestational age 30.5 weeks, range 24-38; median birthweight 1.388 kg, range 0.690-3.510) were each studied...
متن کاملTotal body water and ECFV measured using bioelectrical impedance analysis and indicator dilution in horses.
The purposes of this study were 1) to determine the compartmentation of body water in horses by using indicator dilution techniques and 2) to simultaneously measure bioelectrical impedance to current flow at impulse current frequencies of 5 and 200 kHz to formulate predictive equations that could be used to estimate total body water (TBW), extracellular fluid volume (ECFV), and intracellular fl...