ADC common noise correction and zero suppression in the PIBETA detector

نویسنده

  • E. Frlež
چکیده

We describe a simple procedure for reducing ADC common noise in modular detectors that does not require additional hardware. A method using detector noise groups should work well for modular particle detectors such as segmented electromagnetic calorimeters, plastic scintillator hodoscopes, cathode strip wire chambers, segmented active targets, and the like. We demonstrate a “second pedestal noise correction” method by comparing representative ADC pedestal spectra for various elements of the PIBETA detector before and after the applied correction. PACS Numbers: 07.50.H, 07.05.Hd, 07.05.Kf

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The automatic gain-matching in the PIBETA CsI calorimeter

Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as the spatial and energy resolutions are affected differently. Increased number of individual detectors reduces accidental particle pile-up per detector but int...

متن کامل

روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)

The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...

متن کامل

Evaluation of the Parameters Involved in the Iris Recognition System

Biometric recognition is an automatic identification method which is based on unique features or characteristics possessed by human beings and Iris recognition has proved itself as one of the most reliable biometric methods available owing to the accuracy provided by its unique epigenetic patterns. The main steps in any iris recognition system are image acquisition, iris segmentation, iris norm...

متن کامل

Phase Noise Suppression in OFDM Including Intercarrier Interference

In order to suppress the influence of phase noise in OFDM communications systems, the correction of the common phase error (CPE) does not suffice always, especially when high data rates are required. In this paper we introduce a phase noise suppression algorithm which estimates higher spectral components of the phase noise process in the frequency domain, thus characterizing the deviation from ...

متن کامل

Optimizing Technology Research of Imaging Quality on X-ray Digital Imaging

It has become an inevitable development that X-ray digital imaging detectors replace film-screen. The imaging quality of X-ray digital detector could not reach the level of film-screen due to its unique characteristics. It is the key that to research the method of improving and optimizing the digital imaging quality. The main factors to impact X-ray digital imaging quality is inherent non-unifo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000