Color isodose curve plotter applied to beam focus radiography.
نویسنده
چکیده
An apparatus was constructed to facilitate superimposition of the beam focus radiogram upon the axial transverse tomogram, in order to guide subsequent radia tion therapy more accurately. The apparatus automatically draws six isodose curves in three colors, by plotting the relative doses of the beam focus radiogram. In addition, the isodose chart was made at the same magnification as that of the axial transverse tomogram. A satisfactory and reliable technique was achieved. The accuracy and the reproducibility of the apparatus was good. Clinical applica tion of this method to a case of hypophyseal tumor is described.
منابع مشابه
Detection of electron beam energy variations using a computed radiography system
A method to evaluate the electron beam energy constancy by employing the computed radiography (CR) system has been developed. In this method, a right triangular plastic wedge is used to produce a curve of the CR storage phosphor plate signal versus the wedge thickness. The curve, which resembles the percentage depth ionization curve of the clinical electron beams, can be used to derive the ener...
متن کاملSuperimposition of beams to vary shot size in gamma knife stereotactic radiosurgery
The Leksell Gamma Knife [Elekta Corp] uses helmets as collimators to produce four standard beam sizes. The nominal beam diameters are 18, 14, 8, and 4 mm. During computer treatment planning for gamma knife stereotactic radiosurgery, the size of the treated volume may differ from the standard beam sizes. To maintain conformality of the isodose curves to the treated volume, beam sizes may be supe...
متن کاملEffect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy
In lung stereotactic body radiotherapy (SBRT) cases, the pencil beam (PB) dose calculation algorithm is known to overestimate target dose as compared to the more accurate Monte Carlo (MC) algorithm. We investigated whether changing the normalized prescription isodose line affected the magnitude of MC vs. PB target dose differences. Forty-eight patient plans and twenty virtual-tumor phantom plan...
متن کاملInvestigation of the Field Size Effect on Wedge Field Isodose Curves Angle for Two Energies; 6 & 18 MV, produced by VARIAN 2100C Linac
Introduction: Nowadays, considerable developments in the field of radiotherapy have been achieved. They include the advances made in the equipments and treatment planning techniques which require highly complex calculations. Such achievements have made it possible to treat cancer patients not only with higher radiation dose but also with higher precision and con...
متن کاملA comparison of dose distribution from Manchester-style and Fletcher-style intracavitary brachytherapy applicator systems in cervical cancer
PURPOSE During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Fletcher-style applicator systems. MATERIAL AND METHODS After completion of EBR...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Tohoku journal of experimental medicine
دوره 92 3 شماره
صفحات -
تاریخ انتشار 1967