Predictors of atrial fibrillation recurrence after atrial fibrillation ablation with cryoballoon.

نویسندگان

  • Banu Evranos
  • Kudret Aytemir
  • Ali Oto
  • Sercan Okutucu
  • Uğur Karakulak
  • Levent Şahiner
  • Barış Kaya
  • Giray Kabakçı
چکیده

BACKGROUND Catheter ablation of atrial fibrillation is recommended for patients with symptomatic paroxysmal atrial fibrillation (PAF) despite anti-arrhythmic drugs (AADs). Radiofrequency ablation is widely accepted as an effective treatment for PAF. Cryoenergy by cryoballoon technique is an alternative to radiofrequency (RF) ablation. Cryoballoon ablation is safe, and has a similar success rate in comparison to RF ablation. AF recurrence with cryoballoon ablation is roughly 30%. The aim of this study is to determine the predictors of AF recurrence after cryoballoon ablation. METHODS AND RESULTS Sixty one patients with symptomatic PAF despite AADs without structural heart disease were included. Cryoballoon ablation was performed in 60 patients (36 males, mean age: 54.6 ± 10.7, mean left atrium size: 3.74 ± 0.39 mm). Transthoracic echocardiography including tissue Doppler imaging was performed in all subjects during sinus rhythm at baseline and after the ablation. Intra-atrial and inter-atrial electromechanical delays, and PA-lateral were measured. All patients were scheduled for 24 h Holter recording at baseline and at 3, 6, 9 months follow-up. Venous samples were collected to measure CK-MB, Troponin-T (TnT), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) levels at baseline and 24 h after ablation. Median follow up was 10 (8-12) months. Forty eight (80%) patients were in sinus rhythm during the follow up. In receiver operating curve (ROC) analysis, intraleft atrial electromechanical delay and PA-lateral achieve an area under the curve (AUC) 0.97 (p < 0.001) and 0.69 (p < 0.001) for the ability to predict AF recurrence. A cut-off value for baseline intra left atrial electromechanical delay of 29.5 ms predicted AF recurrence with sensitivity of 85% and specifity of 98%. A cut-off value for PA-lateral of 125 ms predicted AF recurrence with sensitivity of 80% and specifity of 90%. In ROC analysis, age achieves an AUC 0.822 (p = 0.006) for the ability to predict AF recurrence. A cut-off value for age of 64 predicted AF recurrence with sensitivity of 71% and specifity of 90%. Early recurrence of AF (HR = 60, 95% CI 18.61-417.86, p < 0.001) predicted also late recurrence of AF. CONCLUSIONS The increase in AF recurrence by increased intraleft atrial electromechanical delay, PA-lateral and older age show the importance of substrate in AF mechanism. Early recurrence was the strongest predictor of late recurrence of AF; therefore, existence of blanking period for cryoballoon ablation should be questioned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence and significance of early recurrences of atrial fibrillation after cryoballoon ablation: insights from the multicenter Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP AF) Trial.

BACKGROUND Early recurrence of atrial fibrillation (ERAF) is common after radiofrequency catheter ablation for AF. We sought to determine the incidence and prognostic significance of ERAF after cryoballoon ablation. Moreover, the benefit of early reablation for ERAF after cryoballoon ablation is undetermined. METHODS AND RESULTS The Sustained Treatment of Paroxysmal Atrial Fibrillation (STOP ...

متن کامل

Predictors of atrial fibrillation recurrence after cryoballoon ablation

OBJECTIVE Cryoballoon ablation (CA) is a safe and efficient method for pulmonary vein isolation in the treatment of paroxysmal atrial fibrillation (AF). There are conflicting results about the predictors of AF recurrence. The aim of this study is to evaluate the role of hematological indices to predict AF recurrence after CA. METHODS A total of 49 patients (mean age 58.3±12.2 years, 51.02% fe...

متن کامل

Cryoballoon ablation in young patients with lone paroxysmal atrial fibrillation.

INTRODUCTION AND OBJECTIVES Long-term efficacy following cryoballoon ablation of lone paroxysmal atrial fibrillation remains unknown. We describe long-term follow-up results of the single cryoballoon ablation procedure. METHODS Pulmonary vein isolation was performed in 103 patients (72 male; median age 52 years) with symptomatic lone paroxysmal atrial fibrillation. The end-point of this obser...

متن کامل

Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.

Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiology journal

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2013