Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis

نویسندگان

  • Klas Gustafson
  • Stig S Jakobsen
  • Nina D Lorenzen
  • Jacob P Thyssen
  • Jeanne D Johansen
  • Charlotte M Bonefeld
  • Maiken Stilling
  • Thomas Baad-Hansen
  • Kjeld Søballe
چکیده

BACKGROUND Metal-on-metal (MOM) total hip arthroplasties were reintroduced because of the problems with osteolysis and aseptic loosening related to polyethylene wear of early metal-on-polyethylene (MOP) arthroplasties. The volumetric wear rate has been greatly reduced with MOM arthroplasties; however, because of nano-size wear particles, the absolute number has been greatly increased. Thus, a source of metal ion exposure with the potential to sensitize patients is present. We hypothesized that higher amounts of wear particles result in increased release of metal ions and ultimately lead to an increased incidence of metal allergy. METHODS 52 hips in 52 patients (median age 60 (51-64) years, 30 women) were randomized to either a MOM hip resurfacing system (ReCap) or a standard MOP total hip arthoplasty (Mallory Head/Exeter). Spot urine samples were collected preoperatively, postoperatively, after 3 months, and after 1, 2, and 5 years and tested with inductively coupled plasma-sector field mass spectrometry. After 5 years, hypersensitivity to metals was evaluated by patch testing and lymphocyte transformation assay. In addition, the patients answered a questionnaire about hypersensitivity. RESULTS A statistically significant 10- to 20-fold increase in urinary levels of cobalt and chromium was observed throughout the entire follow-up in the MOM group. The prevalence of metal allergy was similar between groups. INTERPRETATION While we observed significantly increased levels of metal ions in the urine during the entire follow-up period, no difference in prevalence of metal allergy was observed in the MOM group. However, the effect of long-term metal exposure remains uncertain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

OBJECTIVES To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. DESIGN Retrospective cohort study. SETTING English hospital episode statistics database linked to mortality records from the Office for National Statistics. POPULATION All adults who underwent primary elective hip replacement for osteoarthritis from ...

متن کامل

Ion Release from Metal-on-metal Hip Resurfacing Implants Does Not Differ from Standard Metal-on-metal Total Hip Replacement

STANDARD METAL-ON-METAL TOTAL HIP REPLACEMENT *Moroni A, **Savarino L, *Cadossi M, **Greco M, **Baldini N, *Giannini S * Rizzoli Orthopaedic Institute, Bologna, Italy **Laboratory for Pathophysiology of Orthopaedic Implants, Rizzoli Orthopaedic Institute, Bologna, Italy [email protected] INTRODUCTION Modern metal-on-metal (MOM) hip resurfacing has been introduced as a less invasive method of join...

متن کامل

Ongoing problems with metal-on-metal hip implants.

Major advances in total hip replacement have occurred since the prosthesis was first developed by Charnley in the 1960s. Yet substantial concerns currently exist over newer hip implants as a result of rising revision rates and increased risk of cancer. By the 1980s revision rates of total hip replacements were as low as 20% after 15 years of follow-up. Throughout this era, the main focus was re...

متن کامل

Brain structure and function in patients after metal-on-metal hip resurfacing.

BACKGROUND AND PURPOSE Hip prostheses that use a metal-on-metal articulation expose the brain to elevated metal concentrations that, in acute excess due to prosthesis malfunction, is associated with neurologic damage, including visual and hearing loss and motor deficits. Here, we examined whether chronic exposure to lower elevated metal levels, typical of well-functioning prostheses, also affec...

متن کامل

Metal-on-Metal Hip Prostheses and Systemic Health: A Cross-Sectional Association Study 8 Years after Implantation

There is public concern over the long term systemic health effects of metal released from hip replacement prostheses that use large-diameter metal-on-metal bearings. However, to date there has been no systematic study to determine which organs may be at risk, or the magnitude of any effect. We undertook a detailed cross-sectional health screen at a mean of 8 years after surgery in 35 asymptomat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 85  شماره 

صفحات  -

تاریخ انتشار 2014