Improved survival for anatomic total shoulder prostheses

نویسندگان

  • Bjørg T S Fevang
  • Tone W Nystad
  • Arne Skredderstuen
  • Ove N Furnes
  • Leif I Havelin
چکیده

BACKGROUND AND PURPOSE Previously, implant survival of total shoulder prostheses was reported to be inferior to that of hemiprostheses. However, the use of total prostheses has increased in Norway due to reported good functional results. On this background, we wanted to study implant survival of 4 major shoulder prosthesis types in Norway between 1994 and 2012. PATIENTS AND METHODS The study population comprised 4,173 patients with shoulder replacements reported to the Norwegian Arthroplasty Register, including 2,447 hemiprostheses (HPs), 444 anatomic total prostheses (ATPs), 454 resurfacing prostheses (RPs), and 828 reversed total prostheses (RTPs). Three time periods were compared: 1994-1999, 2000-2005, and 2006-2012. Kaplan-Meier failure curves were used to compare implant failure rates for subgroups of patients, and adjusted risks of revision were calculated using Cox regression analysis. RESULTS For prostheses inserted from 2006 through 2012, the 5-year survival rates were 95% for HPs (as opposed to 94% in 1994-1999), 95% for ATPs (75% in 1994-1999), 87% for RPs (96% in 1994-1999), and 93% for RTPs (91% in 1994-1999). During the study period, the implant survival improved significantly for ATPs (p < 0.001). A tendency of better results with acute fracture and worse results in sequelae after previous fractures was seen in all time periods. INTERPRETATION The 5-year implant survival rates were good with all prosthesis types, and markedly improved for anatomic total prostheses in the last 2 study periods. The better functional results with total shoulder prostheses than with hemiprostheses support the trend towards increased use of total shoulder prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?

Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...

متن کامل

Polyethylene Wear in Anatomic and Reversed Shoulder Prostheses

INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...

متن کامل

Failure of Anatomic Total Shoulder Arthroplasty with Revision to Another Anatomic Total Shoulder Arthroplasty

Background: While outcomes of primary anatomic total shoulder arthroplasty (aTSA) are generally favorable, resultsafter revision procedures are less reliable. This study examines the functional outcomes, complications, and implantsurvival in patients who underwent revision of aTSA to aTSA.Methods: Patients who underwent revision aTSA were identified from 2008-2015. Demographic, clinical, surgic...

متن کامل

Short-Term Results of the DePuy Global Unite Platform Shoulder System: A Two-Year Outcome Study

Background: The Global Unite Shoulder System is the next generation of implant from the Depuy Global Shoulderline. The primary feature of the Global Unite is adaptability through the interchangeable modular bodies, modular suturecollars, and stems. Short-term functional and radiographic outcomes of the Global Unite Platform Shoulder Systemwere assessed as well as complication and revision rates...

متن کامل

Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results.

BACKGROUND Several stemless shoulder implants are available on the market, but only a few studies have presented results with sufficient mid- to long-term follow-up. The present study evaluated clinical and radiologic outcomes 9 years after anatomic stemless shoulder replacement. METHODS This is a prospective cohort study evaluating the stemless shoulder prosthesis since 2005. Anatomic stemle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2015