Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases.

نویسندگان

  • Jeff R Ward
  • Peter Parashos
  • Harold H Messer
چکیده

The removal of fractured rotary nickel-titanium instruments from small, curved root canals is one of the most complex operative procedures in endodontics. There have been many different devices and techniques developed to remove fractured instruments, but none are consistently successful and all show a high incidence of canal damage such as perforation. A technique using a staging platform and the use of modern ultrasonic tips with direct visualization through a dental operating microscope has recently been evaluated. The use of this technique in clinical practice is described in 24 cases and illustrated by 3 cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Success of ultrasonic technique in removing fractured rotary nickel-titanium endodontic instruments from root canals and its effect on the required force for root fracture.

INTRODUCTION Fracture of rotary nickel-titanium files is a real concern among endodontists; it affects the long-term prognosis of treatment. Ultrasound is a favorable technique for removing broken files, although it may result in some complications. The aim of this study was to determine the success rate of ultrasonic technique in removing file fragments and to evaluate its influence on the for...

متن کامل

Ultrasonic Treatment Endodontice

The aim of this study is to demonstrate the ability of our ultrasonic endodontic dental device with rotary nickel-titanium alloy instruments for the root canal treatment. This study is aimed at investigating the cleaning and shaping efficacy with “Ultrasonic device for endodontic treatment of dental’s canals. The purpose of root canal treatment is to get rid of the damaged pulp and the bacteria...

متن کامل

ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy.

AIM To investigate physical parameters for ProTaper nickel-titanium (NiTi) rotary instruments whilst preparing curved canals in maxillary molars in vitro. METHODOLOGY A novel torque-testing platform was used to prepare root canals in 15 extracted human maxillary molars with ProTaper rotary instruments. Peak torque and force was registered along with numbers of rotations required to shape the ...

متن کامل

Ultrasonic Technique to Retrieve a Rotary Nickel-Titanium File Broken Beyond the Apex and a Stainless Steel File from the Root Canal of a Mandibular Molar: A Case Report

During endodontic treatment, clinicians may face endodontic procedural mishaps such as broken instruments, which is a complex situation especially when the file breaks beyond the apex. This condition is associated with potential risk of contamination, which compromises the healing process. Management of a broken instrument beyond the apex is difficult and time consuming and requires creativity ...

متن کامل

Tips to avoid instrument separation in endodontics.

procedural accidents and obstacles to normally routine therapy, at almost any stage of treatment. One of these procedural problems is intracanal instrument fracture. Fractured root canal instruments may include endodontic files (Figure 1) and Gates Glidden burs. Instruments are made from nickel titanium (NiTi), stainless steel or carbon steel. Fracture often results from incorrect use or overus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 29 11  شماره 

صفحات  -

تاریخ انتشار 2003