Development and Validation of a Stability-Indicating Liquid Chromatographic Method for the Determination of Cefditoren Pivoxil in Presence of Degradation Products
نویسنده
چکیده
A novel stability indicating liquid chromatographic method was developed for the determination of Cefditoren pivoxil in presence of degradation products using Zorbax SB C18 (150 mm × 4.6 mm i.d., 3.5 μm particle size) column with a flow rate 1.0 mL/min (UV detection 210 nm). Linearity was observed over a concentration range 0.1–200 μg/mL with regression equation y = 34809 x + 30603 (R = 0.9994). Forced degradation studies were performed and Cefditoren pivoxil is reported to be highly sensitive towards alkaline conditions in comparison to oxidation. The method was validated as per ICH guidelines.
منابع مشابه
Development and validation of the stability-indicating LC–UV method for the determination of Cefditoren pivoxil
An isocratic RP-HPLC method was developed for the determination of Cefditoren pivoxil in pharmaceutical formulations using a C-18 column with water-acetonitrile (50:50, v/v) as mobile phase and flow rate 1.2 mL/min (UV detection at 218 nm). Linearity was observed in the concentration range 1.0-250 μg/mL (R2=0.999) with regression equation y=24194x+10749. The forced degradation studies were perf...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کامل