Evaluation of the usefulness of coronary catheters and 4 Fr insertion sets for transradial access coronarography in comparison with catheters and 5 Fr sets

نویسندگان

  • Piotr Chodór
  • Stanisław Morawski
  • Sylwia Sulik-Gajda
  • Nela Ramus
  • Jacek Kowalczyk
  • Grzegorz Honisz
  • Krzysztof Wilczek
  • Beata Średniawa
  • Zbigniew Kalarus
چکیده

INTRODUCTION Application of transradial arterial access during coronarography, besides pain, means faster patient mobilization and fewer complications. During those procedures, vascular sheaths and 5/6 Fr catheters, and lately 4 Fr catheters, are used. AIM To assess the usefulness of 4 Fr catheters and sheaths in comparison to 5 Fr in diagnostic coronarography. MATERIAL AND METHODS In the period from 5.12.2010 to 27.02.2012, a group of patients who had coronarography with a 4 Fr catheter (n = 20) and a 5 Fr catheter (n = 20) were studied. Technical issues and potential problems related to the use of each catheter were analyzed. Morphology, biochemical parameters, and local complications were analyzed. The assessment included pain intensification during catheter removal and insertion in the VAS/numerical (0-10)/verbal scales and the quality of image obtained during the coronarography. RESULTS All the angiograms obtained during all the interventions were of diagnostic value and in invasive cardiologists' opinions, they did not differ statistically in clarity. Moreover, there were no statistically significant differences in radiation/fluoroscopy time, amount of contrast medium, or morphological and biochemical parameters. The size of hematomas in the 4 Fr group was 17.55 ±14.6 cm(2), and in the 5 Fr group 31.07 ±32.11 cm(2), p = 0.12. The average intensity of pain felt during the intervention/at the time of its removal and insertion in the numerical scale was in the 4 Fr group 0.65 ±0.93/0.55 ±0.94 and in the 5 Fr group 1.88 ±1.64/1.42 ±1.61, p < 0.05. CONCLUSIONS Application of 4 Fr catheters allows one to perform a diagnostic procedure with a small number of local and hemorrhagic complications comparable with 5 Fr catheters. Due to reduced pain, it is appropriate to continue studies with the use of 4 Fr catheters and sheaths.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters

INTRODUCTION Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and con...

متن کامل

Safety and feasibility of the new 5 Fr Glidesheath Slender.

The aim of this study was to evaluate the safety and feasibility of the new 5 Fr Glidesheath Slender (GSS). The transradial (TR) approach has become popular because of several advantages, such as a reduced rate of vascular access site complications. However, because the radial artery is narrow, a limitation of TR access is the potential for artery spasm or occlusion. Studies of radial artery si...

متن کامل

Use of 5 French Guiding Catheters in Transradial Coronary Intervention Procedures

Background: Transradial coronary intervention (TRI) is a widely practiced procedure in Taiwan. Most TRIs are performed using 6 French guiding catheters. Use of smaller-sized vascular sheaths and guiding catheters may further decrease the incidence of vascular access complication, but demand more operator experience and skills in manipulation of the catheter. We report our experience in using 5 ...

متن کامل

Successful percutaneous coronary intervention using a 4-in-3 “Slender Mother and Child” PCI technique

We report two cases of successful percutaneous coronary intervention (PCI) using a 4-in-3 "Slender Mother and Child" PCI technique. In both cases, coronary angiography revealed severe stenosis of the right coronary artery (RCA). In both cases, 5-Fr sheathless guiding catheters were inserted into the RCA (virtual 3-Fr PCI) but stents could not pass through because of stents previously implanted ...

متن کامل

Transradial percutaneous coronary intervention for chronic total occlusion of coronary artery disease using sheathless standard guiding catheters

OBJECTIVES Our aim was to evaluate the feasibility and safety of routine transradial approach (TRA) percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions using the sheathless technique with standard guiding catheters. BACKGROUND Transradial approach PCI was applied for CTO lesions. A major limitation of TRA CTO PCI is the inability to use large guiding catheters b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013