Distal protection devices during percutaneous coronary and carotid interventions

نویسندگان

  • Panayotis Fasseas
  • James L Orford
  • Ali E Denktas
  • Peter B Berger
چکیده

Distal embolization of particulate matter complicates percutaneous coronary and peripheral interventions more often than had been recognized until recently. A number of distal protection devices are under development. The PercuSurge GuardWiretrade mark is a balloon occlusion thrombectomy device approved by the United States Food and Drug Administration for saphenous vein graft intervention. A number of filter devices utilize an expandable filter mounted on the angioplasty guidewire to facilitate entrapment of particles and safe removal. The Parodi Anti-Emboli Systemtrade mark is an example of a catheter occlusion device that establishes protection by reversing blood flow in the target vessel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An update on herpes virus infections in graft recipients.

percutaneous coronary and carotid interventions. Curr Control Trials Cardiovasc Med 2001; 2: 286–291 11. Angelini A, Reimers B et al. Cerebral protection during carotid artery stenting. Stroke 2002; 33: 456–461 12. Webb JG, Carere RGC, Virmani R et al. Retrieval and analysis of particulate debris after saphenous vein graft intervention. J Am Col Cardiol 1999; 34: 468–475 13. Baim DS, Wahr D, Ge...

متن کامل

A novel filter-based distal embolic protection device for percutaneous intervention of saphenous vein graft lesions: results of the AMEthyst randomized controlled trial.

OBJECTIVES We sought to evaluate the relative safety and efficacy of the novel Interceptor PLUS Coronary Filter System (Medtronic Vascular, Santa Rosa, California) compared with approved embolic-protection devices (e.g., GuardWire, Medtronic Vascular/FilterWire EZ, Boston Scientific, Natick, Massachusetts) during percutaneous coronary intervention (PCI) of degenerative saphenous vein grafts (SV...

متن کامل

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Embolic Protection Devices in Aortocoronary Saphenous Vein Graft Intervention

E mbolic protection devices (EPDs) were first developed to provide cerebral protection during carotid artery stenting and have led to marked reductions in the combined endpoints of stroke or death.1,2 Therefore, it was natural that these devices should be applied to native coronary and aortocoronary saphenous vein graft (SVG) interventions to reduce clinically significant atheroand thromboembol...

متن کامل

Effect of percutaneous coronary interventions for in-stent restenosis in degenerated saphenous vein grafts without distal embolic protection.

OBJECTIVES This study was designed to investigate the impact of percutaneous coronary interventions (PCIs) in degenerated saphenous vein grafts (SVGs) without distal embolic protection. BACKGROUND Distal embolic protection devices have been shown to reduce the incidence of no reflow/slow flow during PCI of de novo lesions in degenerated SVGs. It is unclear whether PCI of in-stent restenosis (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Current Controlled Trials in Cardiovascular Medicine

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2001