The Present Status of the Low Energy Neutron Source
نویسندگان
چکیده
The Low Energy Neutron Source (LENS) at Indiana University produced its first neutrons in late 2004, and has been engaged in a series of facility upgrades since that time. Among the important developments over the past two years have been the commissioning of klystron-based RF systems, the demonstration of beam peak proton beam currents of more than 20mA, and the low-power operation of a methane moderator at temperatures below 10K. In this talk we will review the present status of the facility and review some of these recent results along with a few of the milestones anticipated for the construction phase over the next 10 months.
منابع مشابه
بررسی امکان استفاده از چشمه های نوترونی رادیوایزوتوپی در نوترون درمانی با بور
Background : Performing successful BNCT experiments needs a suitable neutron source. Important factors of the neutron beam are flux and energy that are very important in the selection of neutron source. In most centers that use this method for treatment, reactor is a neutron source, which according to characteristics of the reactor appropriated neutrons are very high. High cost of constructin...
متن کاملA Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source
Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose enhancement in the tumors loaded with these materials. Objective: The purpose of this study is to evaluate dose distribution in the presence of 10B, 157Gd and 33S neutron...
متن کاملCharacterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron
Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally...
متن کاملEstimation of neutron and gamma dose in the MNSR research reactor
In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...
متن کاملTitle Design of light element analysis system in BNCT and every NCT
Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...
متن کاملThe study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF
The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...
متن کامل