Otr Polarization Effects in Beam-profile Monitors at the Fermilab A0 Photoinjector*

نویسندگان

  • A. Lumpkin
  • A. Johnson
  • J. Ruan
  • J. Santucci
چکیده

Optical transition radiation (OTR) imaging for transverse beam-size characterization is a well-established technique at many accelerators including the Fermilab A0 photoinjector (A0PI) facility. With low beam energies of 14-15 MeV and emittances of 3 mm mrad, one observes beam sizes of 0.8 to 1.5 mm (sigma). However, the use of 50-μm wide slits to sample the beam’s transverse phase spaces significantly alters the required resolution of the converter screen and imaging system. Slit-image sizes of about sigma =100 μm or less are observed, depending on drift distance and beam divergence. Moreover, the OTR polarized component perpendicular to the narrow beam dimension systematically gave us ~20-μm smaller projected image sizes than those with the total OTR intensity. This is one of the first reports of this polarization effect at such a low-gamma regime (~30).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First observation of the exchange of transverse and longitudinal emittances.

An experimental program to demonstrate a novel phase-space manipulation in which the horizontal and longitudinal emittances of a particle beam are exchanged has been completed at the Fermilab A0 Photoinjector. A new beam line, consisting of a TM(110) deflecting mode cavity flanked by two horizontally dispersive doglegs has been installed. We report on the first direct observation of transverse ...

متن کامل

Transverse and longitudinal beam dynamics studies at the Fermilab photoinjector

The Fermilab photoinjector produces electron bunches of 1–12 nC charge with an energy of 16–18 MeV. Detailed measurements and optimization of the transverse emittance have been carried out for a number of beam line optics conditions, and at a number of beam line locations. The length of the bunches has also been measured, first for an uncompressed beam (as a function of the charge) and then for...

متن کامل

Improvement in the laser system for the A0 TTF Photoinjector

The production of high charge and high brightness electron beams places increasingly challenging demands on the drive laser used at the A0 photoinjector in the Fermilab. The IR and UV laser pulse lengths need to be optimized for such purpose. We have experimentally investigated two different ways to change the UV laser pulse length on the cathode; either by changing the bandwidth of the oscilla...

متن کامل

Initial Observations of Micropulse Elongation of Electron Beams in a Scrf Accelerator*

Commissioning at the SCRF accelerator at the Fermilab Accelerator Science and Technology (FAST) Facility has included the implementation of a versatile bunch-length monitor located after the 4-dipole chicane bunch compressor for electron beam energies of 20-50 MeV and integrated charges in excess of 10 nC. The team has initially used a Hamamatsu C5680 synchroscan streak camera to assess the eff...

متن کامل

Considerations on the Diffraction Limitations to the Spatial Resolution of Optical Transition Radiation

The interest in using optical transition radiation (OTR) in high energy (multiGeV) beam diagnostics has motivated theoretical and experimental investigations on the limitations brought by diffraction on the attainable resolution. This paper presents calculations of the diffraction effects in an optical set-up using OTR. The OTR diffraction pattern in a telescopic system is calculated taking int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010