Risk of Pacemaker Patients by TASER X26 Contact Mode Application

نویسندگان

  • Norbert Leitgeb
  • Florian Niedermayr
  • Robert Neubauer
  • Gerhard Loos
چکیده

The prevalence of pacemaker patients among the general population and of conducted energy devices (CED) for law enforcement and self-defence is increasing. Consequently, the question whether cardiac pacemaker (CPM) patients are on particular risk becomes increasingly important. The risk of Taser X26 electric interference with implanted CPM has been investigated by numerical simulation at MRI-based anatomical models of CPM patients with devices implanted at conventional sites (left pectoral, right pectoral and abdominal) and with the monopolar CPM electrode placed at the ventricular apex. In spite of 10 fold higher peak voltages the different coupling conditions make Taser-induced CPM interference voltages lower than those caused by external cardiac defibrillators. It is shown that electric interference considerably depends on ECD electrode orientation. The most unfavourable conditions are encountered with ECD electrodes aligned with the line from the CPM electrode tip to CPM can (EPC line). It could be shown that worst case interference voltages of monopolar pacemakers of any kind of implantation remain below the pulse immunity level as defined in safety standards of implantable cardiac pacemakers and of cardioverter defibrillators. However, interference voltages exceed CPM sensing thresholds. Therefore, capturing should be expected at Taser X26 contact mode application at any position at the upper part of the body including the abdomen, both at frontal and dorsal positions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Defence Scientific Advisory Council Sub-Committee on the Medical Implications of Less-Lethal Weapons (DOMILL) Statement on the Medical Implications of Use of the Taser X26 and M26 Less-Lethal Systems on Children and Vulnerable Adults

2. DOMILL has issued five previous statements relating to the medical implications of the Taser M26 and Taser X26 less-lethal systems. 4 The Taser X26 conducted energy device was introduced into UK policing in 2005 as a replacement for the Taser M26. Recent data from the Home Office Centre for Applied Science and Technology (CAST) indicate that the Taser X26 is the device primarily in use by th...

متن کامل

Repetitive TASER X26 discharge resulted in adverse physiologic events with a dose-response relationship related to the duration of discharge in anesthetized swine model.

The objectives of our study were to investigate the dose-response relationship of the TASER X26 discharge duration in an anesthetized swine model. Fourteen swines were anesthetized and then exposed to TASER X26 discharge for 5 sec (n = 5) or for 10 sec (n = 6). The sham control group (n = 3) was anesthetized and studied using the same protocol except TASER X26 discharges during the experiments....

متن کامل

Echocardiographic evaluation of TASER X26 probe deployment into the chests of human volunteers.

Several animal studies have shown that the TASER X26 (TASER International, Scottsdale, Ariz) conducted electrical weapon can electrically capture the myocardium when discharged on the thorax. These results have not been reproduced in human echocardiographic studies. A primary limitation of those human studies is that the TASER device was connected by taping the wires into conductive gel on the ...

متن کامل

Muscle contraction during electro-muscular incapacitation: A comparison between square-wave pulses and the TASER(®) X26 Electronic control device.

Electronic control devices (including the Advanced TASER(®) X26 model produced by TASER International) incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, effects of monophasic square waves with different parameters were compared with those of the X26 electronic control device, using two animal models (frogs and sw...

متن کامل

TASER X26 discharges in swine produce potentially fatal ventricular arrhythmias.

OBJECTIVES Data from the authors and others suggest that TASER X26 stun devices can acutely alter cardiac function in swine. The authors hypothesized that TASER discharges degrade cardiac performance through a mechanism not involving concurrent acidosis. METHODS Using an Institutional Animal Care and Use Committee (IACUC)-approved protocol, Yorkshire pigs (25-71 kg) were anesthetized, paralyz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013