Coherency Identification of Generators Using a PAM Algorithm for Dynamic Reduction of Power Systems

نویسندگان

  • Gi-Chan Pyo
  • Seung-Il Moon
چکیده

This paper presents a new coherency identification method for dynamic reduction of a power system. To achieve dynamic reduction, coherency-based equivalence techniques divide generators into groups according to coherency, and then aggregate them. In order to minimize the changes in the dynamic response of the reduced equivalent system, coherency identification of the generators should be clearly defined. The objective of the proposed coherency identification method is to determine the optimal coherent groups of generators with respect to the dynamic response, using the Partitioning Around Medoids (PAM) algorithm. For this purpose, the coherency between generators is first evaluated from the dynamic simulation time response, and in the proposed method this result is then used to define a dissimilarity index. Based on the PAM algorithm, the coherent generator groups are then determined so that the sum of the index in each group is minimized. This approach ensures that the dynamic characteristics of the original system are preserved, by providing the optimized coherency identification. To validate the effectiveness of the technique, simulated cases with an IEEE 39-bus test system are evaluated using PSS/E. The proposed method is compared with an existing coherency identification method, which uses the K-means algorithm, and is found to provide a better estimate of the original system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online Aggregation of Coherent Generators Based on Electrical Parameters of Synchronous Generators

This paper proposes a novel approach for coherent generators online clustering in a large power system following a wide area disturbance. An interconnected power system may become unstable due to severe contingency when it is operated close to the stability boundaries. Hence, the bulk power system controlled islanding is the last resort to prevent catastrophic cascading outages and wide area bl...

متن کامل

Identification of Coherent Generators for Large-Scale Power Systems Using Fuzzy Algorithm

This paper presents a new proposed method for identifying the coherent groups of generators for any large power system, this is based on two different techniques; the first one is based on applying two proposed coherency criterions introduced by using time response of the linearized power system model; the second one is based on the application of Fuzzy C-Means clustering algorithm (FCM). Also ...

متن کامل

Evaluation of Coherency-based Aggregation Methods

This project applies coherency methods for dynamic analysis of power systems. It has been observed that in case of disturbances machines swing together, forming groups of coherent generators. In [1], a dynamic network reduction is described based on a slow-coherency method, aggregating coherent generators into one equivalent machine. In [2] it is demonstrated that such methods can also be used ...

متن کامل

Simultaneous RPD and SVC Placement in Power Systems for Voltage Stability Improvement Using a Fuzzy Weighted Seeker Optimization Algorithm

Voltage stability issues are growing challenges in many modern power systems. This paper proposes optimizing the size and location of Static VAR Compensator (SVC) devices using a Fuzzy Weighted Seeker Optimization Algorithm (FWSOA), as an effective solution to overcome such issues. Although the primary purpose of SVC is bus voltage regulation, it can also be useful for voltage stability enhance...

متن کامل

Design Optimization for Total Volume Reduction of Permanent Magnet Synchronous Generators

Permanent magnet synchronous generators (PMSGs) are novel generators which can be used in high-performance wind farms. High efficiency and flexibility in producing electricity from variable rotation make them good candidate for wind power applications. Furthermore, because these kinds of generators have no excitation winding, there is no copper loss on rotor; hence, they can operate at high pow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012