Fluctuation analysis of mitochondrial NADH fluorescence signals in confocal and two-photon microscopy images of living cardiac myocytes.

نویسندگان

  • K Blinova
  • C Combs
  • P Kellman
  • R S Balaban
چکیده

A fluctuation analysis was performed on the reduced nicotine adenine dinucleotide (NADH) fluorescence signal from resting rabbit myocytes using confocal and two-photon microscopy. The purpose of this study was to establish whether any co-ordinated biochemical processes, such as binding, metabolism and inner mitochondrial membrane potential, were contributing to NADH signal fluctuations above background instrument noise. After a basic characterization of the instrument noise, time series of cellular NADH fluorescence images were collected and compared with an internal standard composed of NADH in the bathing medium. The coefficient of variation as a function of mean signal amplitude of cellular NADH fluorescence and bathing media NADH was identical even as a function of temperature. These data suggest that the fluctuations in cellular NADH fluorescence in resting myocytes are dominated by sampling noise of these instruments and not significantly modified by biological processes. Further analysis revealed no significant spatial correlations within the cell, and Fourier analysis revealed no coherent frequency information. These data suggest that the impact of biochemical processes, which might affect cellular NADH fluorescence emission, are either too small in magnitude, occurring in the wrong temporal scale or too highly spatially localized for detection using these standard optical microscopy approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protective Effect of Aerobic Training along with Resveratrol on Mitochondrial Dynamics of Cardiac Myocytes in Animal Model of Non-alcoholic Fatty Liver Disease

  Background & objectives: Non-alcoholic fatty liver disease (NAFLD) is associated with mitochondrial dysfunction. The aim of the present study was to examine the effect of aerobic training along with resveratrol on cardiac expression of OPA1 and DRP1 in NAFLD male rats. Methods: In this experimental study, forty eight male Wistar rats were classified into two groups: NAFLD (n=40) and Control-N...

متن کامل

Video-rate scanning two-photon excitation fluorescence microscopy and ratio imaging with cameleons.

A video-rate (30 frames/s) scanning two-photon excitation microscope has been successfully tested. The microscope, based on a Nikon RCM 8000, incorporates a femtosecond pulsed laser with wavelength tunable from 690 to 1050 nm, prechirper optics for laser pulse-width compression, resonant galvanometer for video-rate point scanning, and a pair of nonconfocal detectors for fast emission ratioing. ...

متن کامل

Multimodal SHG-2PF Imaging of Microdomain Ca2+-Contraction Coupling in Live Cardiac Myocytes.

RATIONALE Cardiac myocyte contraction is caused by Ca(2+) binding to troponin C, which triggers the cross-bridge power stroke and myofilament sliding in sarcomeres. Synchronized Ca(2+) release causes whole cell contraction and is readily observable with current microscopy techniques. However, it is unknown whether localized Ca(2+) release, such as Ca(2+) sparks and waves, can cause local sarcom...

متن کامل

Two-Photon Microscopy for Deep Tissue Imaging of Living Specimens

Introduction Two-photon microscopy (2PM) provides threedimensional (3D) and four-dimensional (4D) (x, y, z, t) imaging in living specimens or under experimental physiological conditions very close to live. In conjunction with fluorescent labels, 2PM provides a powerful means of investigating the relationships between structure and function at the microscopic level that are key to understanding ...

متن کامل

Quantitative Analysis of Calcium Spikes in Noisy Fluorescent Background

Intracellular calcium signals are studied by laser-scanning confocal fluorescence microscopy. The required spatio-temporal resolution makes description of calcium signals difficult because of the low signal-to-noise ratio. We designed a new procedure of calcium spike analysis based on their fitting with a model. The accuracy and precision of calcium spike description were tested on synthetic da...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of microscopy

دوره 213 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2004