Plateau iris configuration in eyes with narrow-angle: an ultrasound biomicroscopic study.

نویسندگان

  • Alberto Diniz Filho
  • Sebastião Cronemberger
  • Dollores Martins Ferreira
  • Rafael Vidal Mérula
  • Nassim Calixto
چکیده

PURPOSE To investigate, through ultrasound biomicroscopy images, the presence of plateau iris configuration in eyes with narrow-angle from patients with open-angle glaucoma and in eyes with previous acute primary angle-closure and compare the biometric features of eyes with plateau iris configuration with those of normal eyes. METHODS Ultrasound biomicroscopic images from 196 patients with open-angle glaucoma and narrow-angle and 32 patients with acute primary angle-closure were retrospectively analyzed. The inclusion and specific criteria for the diagnosis of plateau iris configuration was the presence of an anterior positioning of the ciliary processes, supporting the peripheral iris so that it was parallel to the trabecular meshwork; the iris root had a steep rise from its insertion point, followed by a downward angulation from the corneoscleral wall; presence of a central flat iris plane; an absent (complete plateau iris configuration) or partially absent (incomplete plateau iris configuration) ciliary sulcus. The ultrasound biomicroscopic parameters were compared between complete and incomplete plateau iris configuration. The same parameters of both groups were compared with those of normal eyes. The following measurements were performed: anterior chamber depth; angle opening distance at 500 microm from the scleral spur; peripheral iris thickness at 500 microm from the scleral spur; iris-ciliary process distance; trabecular-ciliary process distance and angle recess area. RESULTS Plateau iris configuration was found in 33 eyes of 20 (10.2%) out of 196 patients with open-angle glaucoma and narrow-angle and in 4 eyes of 2 (6.3%) out of 32 patients with acute primary angleclosure. Seventeen (77.3%) patients with plateau iris configuration were female and 5 (22.7%) male. Twenty-three (62.2%) out of 37 eyes had complete plateau iris configuration, and 14 (37.8%) had incomplete plateau iris configuration. Complete and incomplete plateau iris configuration presented similar biometric features with the exception of the iris-ciliary process distance. All plateau iris configuration eyes showed biometric parameters completely different from those of normal eyes except for peripheral iris thickness at 500 microm from the scleral spur. CONCLUSIONS Plateau iris configuration was present in 10.2% of patients with open-angle glaucoma and narrow-angle and in 6.3% of patients with acute primary angle-closure. Biometric features were similar in eyes with complete and incomplete plateau iris configuration with the exception of iris-ciliary process distance. Compared to normal eyes, all plateau iris configuration eyes showed biometric parameters completely different except for peripheral iris thickness at 500 microm from the scleral spur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative biometric study between plateau iris configuration and primary open angle glaucoma with narrow angle.

PURPOSE To investigate biometrically the differences between plateau iris configuration (PIC) eyes and primary open angle glaucoma with narrow angle eyes. METHODS A comparative study involving a case series with 20 eyes of 11 plateau iris configuration patients and 45 eyes of 27 primary open angle glaucoma with narrow angle eyes patients was done. The following measurements were taken: cornea...

متن کامل

Gonioscopic Features in Patients with Acute and Chronic Angle-Closure Glaucoma

Background: A number of ocular biometric parameters, iris hiotologic and anatomic characters have been suggested as inciting factors for converting patients with narrow angle to angle-closure glaucoma. This study was conducted to determine if there was any goniscopic difference between patients with acute angle-closure glaucoma (AACG) and chronic angle-closure glaucoma (CACG). Methods: ...

متن کامل

Pilocarpine induces an increase in the anterior chamber angular width in eyes with narrow angles.

AIM To determine the mechanical effects of pilocarpine on the trabecular-iris angle opening in eyes with narrow angles, compared with its effects on healthy control subjects with wide angles. METHODS A narrow angle was defined as 25 degrees or less of trabecular-iris angle on ultrasound biomicroscopic examination. The change in anterior chamber depth (ACD), trabecular-iris angle (TIA), angle ...

متن کامل

Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy

Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective s...

متن کامل

Plateau Iris – Therapeutic options and functional results after treatment

We present the therapeutic options and functional results in patients with plateau iris (syndrome or configuration) in consecutive case series. Material and method: Our study included newly diagnosed patients with acute angle closure by "plateau iris" (configuration or syndrome), between June 2016 and April 2017. Series of 8 consecutive patients met the inclusion criteria, all being females. Al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 73 2  شماره 

صفحات  -

تاریخ انتشار 2010