Agreement between different parameters of dialysis dose in achieving treatment targets: results from the NECOSAD study.

نویسندگان

  • Karin E Moret
  • Diana C Grootendorst
  • Friedo W Dekker
  • Elizabeth W Boeschoten
  • Raymond T Krediet
  • Saskia Houterman
  • Charles H Beerenhout
  • Jeroen P Kooman
چکیده

BACKGROUND The recommended parameter of dialysis dose differs between K-DOQI and the European Best Practice Guidelines. It is not well known to what extent an agreement exists between the different parameters, nor if target and delivered dialysis dose are prescribed according to the urea reduction rate (URR), single-pool Kt/V (spKt/V) or equilibrated double-pool Kt/V (eKt/V) and which parameter is most strongly related to mortality. METHODS In 830 haemodialysis patients from the NECOSAD cohort URR, spKt/V and eKt/V were calculated and compared according to a classification regarding the recommended treatment targets (70%, 1.4 and 1.2, respectively) as well as minimum delivered dialysis dose (65%, 1.2 and 1.05, respectively). Moreover, the relation between treatment dose and survival was assessed using Cox regression analysis. RESULTS A spKt/V of ≥1.4 and URR ≥70% corresponded with eKt/V ≥1.20 (as reference method) in, respectively, 98.0 and 90.6% of patients. spKt/V of ≥1.2 and URR ≥65% corresponded with eKt/V ≥1.05 in, respectively, 95.5 and 91.2% of patients. Deviations from the reference method were significantly related to differences in urea distribution volume (spKt/V), treatment time (URR) and ultrafiltration volume (URR). The adjusted HR (95% CI) was 0.98 (0.96, 0.99) for URR, 0.51 (0.31, 0.84) for spKt/V and 0.46 (0.30, 0.80) for the eKt/V. CONCLUSION The use of URR leads to larger disagreement with the reference method (eKt/V) treatment target as compared to spKt/V. Low urea distribution volume, short treatment time and low ultrafiltration volumes are predictive parameters for overestimation of dialysis dose when utilizing the alternative methods spKt/V and URR instead of eKt/V. Delivered eKt/V, spKt/V and URR were all positively related to survival.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A free user friendly program for evaluation of radiotherapy plans based on different dose response models

Introduction: Radiotherapy (RT) plan evaluation using dose response models has become a feasible approach in routine clinical practice. Although there are several tools for this task, they suffer from limitations including number of different dose response models and parameters. In the present study, we aimed to develop a free program for RT plan evaluation based on a variety ...

متن کامل

Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

متن کامل

Dosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code

Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...

متن کامل

Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

متن کامل

Evaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study

Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. The most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a Neptun 10PC linac using the Monte Carlo (MC) code. Materials and Methods: The lina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2012