Measuring the Beam Energy with Radiative Return Events
نویسندگان
چکیده
The beam energy at the ILC is needed to a precision of around 10−4 for accurate mass determinations of the top quark, the Higgs boson and in supersymmetry [1]. This measurement will mainly be done with a magnetic spectrometer [2]. However the absolute calibration of such a spectrometer is difficult and in addition the luminosity weighted centre of mass energy is not necessarily identical to twice the beam energy. It is thus very useful to have a method to measure the luminosity weighted centre of mass energy directly from annihilation data. Fortunately this is possible using radiative return events to the Z using the fact that the Z mass is known to very high precision. The method was already pioneered at LEP2, where it was however limited by the available statistics [3, 4, 5].
منابع مشابه
LEP 2 e + e − → ff, γγ(γ): results and interpretations
Results on LEP 2 e + e − → f f and γγ(γ) production are presented. These are compared with Standard Model predictions, and then used to set limits on various New Physics models, including Low Scale Gravity. Finally the status of the LEP beam energy determination from radiative return events is summarised.
متن کاملBalmer line formation in solar flares affected by return currents
Aims. We investigate the effect of the electric return currents in solar flares on the profiles of hydrogen Balmer lines. We consider the monoenergetic approximation for the primary beam and runaway model of the neutralizing return current. Methods. Propagation of the 10 keV electron beam from a coronal reconnection site is considered for the semiempirical chromosphere model F1. We estimate the...
متن کاملThe Radiative Return: a review of experimental results
The radiative return is a new method for hadronic cross section measurements at electron-positron colliders, which are operated at a fixed center-of-mass energy (so-called particle factories). In order to lower the effective hadronic mass Mhadr only such events are taken, in which one of the electrons or positrons has emitted an initial state radiation photon. We present precision measurements ...
متن کاملMeasuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry
Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...
متن کاملar X iv : h ep - p h / 04 02 03 0 v 1 3 F eb 2 00 4 Hadronic cross section from radiative return ∗
Knowledge of the cross section of the electron–positron annihilation into hadrons in the low energy region is crucial for predictions of the hadronic contributions to aμ, the anomalous magnetic moment of the muon, and to the running of the electromagnetic coupling (For reviews see e.g. [1-7]; the most recent experimental result for aμ is presented in [8]). Measurements of the electron–positron ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005