Does two-segment image reconstruction at 64-section CT coronary angiography improve image quality and diagnostic accuracy?
نویسندگان
چکیده
PURPOSE To prospectively evaluate the effect of single- versus two-segment image reconstruction on image quality and diagnostic accuracy at 64-section multidetector computed tomographic (CT) coronary angiography by using conventional coronary angiography as the reference standard. MATERIALS AND METHODS The study design was approved by a human research committee; patients gave informed consent. The study was HIPAA compliant. Forty consecutive patients (22 men, 18 women; mean age, 61 years +/- 8 [standard deviation]) underwent both 64-section multidetector CT coronary angiography and conventional angiography. All data sets were reconstructed by using single- and two-segment image reconstruction algorithms, with resulting temporal resolution of 82.5-165 msec. Two experienced observers independently evaluated image quality and signs of coronary artery disease. A five-level grading scheme was used to grade stenosis (0%, <50%, <70%, <99%, 100%) and image quality (1[unacceptable] to 5[excellent]). Interobserver correlation, Spearman correlation coefficients, and diagnostic accuracy were calculated. RESULTS Six hundred coronary artery segments were visible on conventional angiograms, of which 560 (93.3%) were seen by using single-segment and 561 (93.5%) were seen by using two-segment image reconstruction (P=.35). Mean quality scores were not significantly different (P=.22) for single- (3.1 +/- 0.9) and two-segment (3.2 +/- 0.8) reconstruction. Significantly (P=.03) better image quality was observed for two-segment reconstruction only at heart rates of 80-82 beats per minute, at which temporal resolution was approximately 83 msec. For grading coronary artery stenosis, correlation was 0.64 for single- and 0.66 for two-segment reconstruction (P=.43). Significant stenosis (>50%) was detected on a per-segment basis with 77.1% sensitivity and 98.6% specificity by using single-segment and with 79.2% sensitivity and 99.1% specificity by using two-segment image reconstruction. CONCLUSION At heart rates of more than 65 beats per minute, use of two-segment reconstruction improves image quality at multidetector CT coronary angiography but does not significantly affect overall diagnostic accuracy compared with single-segment reconstruction.
منابع مشابه
ارزش تشخیصی -MSCT آنژیوگرافی با تکنولوژی 64 - Sliceدر مقایسه با آنژیوگرافی مرسوم در شناسایی بیماری شریان کرونری
Background: Multislice computed tomography (MSCT) is a noninvasive method of detecting coronary artery disease (CAD). The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT) in daily practice, without patient selection. Methods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA). The CT system The...
متن کاملCoronary artery bypass grafts: ECG-gated multi-detector row CT angiography--influence of image reconstruction interval on graft visibility.
PURPOSE To evaluate the influence of different reconstruction intervals of retrospectively electrocardiographically (ECG)-gated multi-detector row computed tomographic (CT) angiography on image quality of different segments of various types of coronary artery bypass grafts. MATERIALS AND METHODS Twenty consecutive patients with 62 grafts underwent retrospectively ECG-gated four-channel multi-...
متن کاملEvaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction.
PURPOSE To prospectively compare traditional filtered back projection (FBP) and iterative image reconstruction for the evaluation of heavily calcified arteries with coronary computed tomography (CT) angiography. MATERIALS AND METHODS The study had institutional review board approval and was HIPAA compliant. Written informed consent was obtained from all patients. Fifty-five consecutive patien...
متن کاملThe Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience
OBJECTIVE We wanted to evaluate the image quality, diagnostic accuracy and radiation exposure of 64-slice dual-source CT (DSCT) coronary angiography according to the heart rate in symptomatic patients during daily clinical practice. MATERIALS AND METHODS We performed a retrospective search for the DSCT coronary angiography reports of 729 consecutive symptomatic patients. For the 131 patients ...
متن کاملImage quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.
PURPOSE To evaluate reconstruction intervals and image quality in dual-source computed tomography (DSCT) coronary angiography for optimal placement of the ECG-pulsing window. MATERIALS AND METHODS DSCT coronary angiography was performed in 60 patients. Thirteen datasets were reconstructed in 5% increments from 20-80%. Two readers independently assessed image quality of each segment in each pe...