Surgical Outcomes of Cox-maze IV Procedure Using Bipolar Irrigated Radiofrequency Ablation and Cryothermy in Valvular Heart Disease
نویسندگان
چکیده
BACKGROUND We evaluated the efficacy of Cox-maze IV procedure using bipolar irrigated radiofrequency ablation and cryothermy in chronic atrial fibrillation associated with valvular heart disease. MATERIAL AND METHODS From November 2005 to June 2009, ninety four patients have undergone valvular heart surgery with Cox-maze IV procedure. Preoperative duration of atrial fibrillation was 7.6±6.5 years and follow-up duration was 22.7±12.3 months. RESULTS There were two (2.1%) postoperative deaths not related to maze procedure. Two cerebrovascular accidents, five low cardiac output syndromes and two permanent pacemaker implantations have occurred after surgery. Preoperative ejection fraction on echocardiography was 55.3±8.1% and ejection fraction of postoperative six month was 54.7±6.5%. Left atrial size of preoperative and postoperative were 61.5±11.6 mm and 53.1±8.4 mm at each. Freedom from atrial fibrillation rate at postoperative six-month was 80.7% and the cases of recurrence of atrial fibrillation after six months were three (3.3%). Risk factors for failure or recurrence of maze procedure were old age (p=.010) and preoperative moderate or severe tricuspid regurgitation (p=.033). CONCLUSION The Cox-maze IV procedure using RFBP2 and cryothermy is quite safe and freedom from atrial fibrillation at postoperative 6 month was 82.5%. Risk factors for failure or recurrence of atrial fibrillation after Cox-maze IV were old age and preoperative over moderate tricuspid regurgitation.
منابع مشابه
The Surgical Treatment for Atrial Fibrillation: Ablation Technology and Surgical Approaches
The Cox maze procedure developed originally in 1987 by Dr James Cox has evolved from a "cut and sew" surgical procedure, where the maze was applied using multiple surgical cuts, to an extensive use of surgical ablation technology where ablation lesions are placed with alternative energy sources (radiofrequency, cryothermy, microwave, and high-frequency ultrasound). Furthermore, the procedure ha...
متن کاملA review of current surgical treatment of patients with atrial fibrillation.
Surgical therapy for patients with atrial fibrillation has undergone significant advances over the past 30 years. The Cox Maze III technique is currently the gold standard of care for these patients. However, Maze IV, a less complex procedure using alternative energy sources, is rapidly replacing the Cox Maze III in clinical practice. The use of alternative energy sources such as cryothermy and...
متن کاملEfficacy of catheter ablation and surgical CryoMaze procedure in patients with long-lasting persistent atrial fibrillation and rheumatic heart disease: a randomized trial.
AIMS Catheter ablation and surgical Maze procedure are effective in treating atrial fibrillation (AF) patients. However, there is no study that compares the effect of circumferential pulmonary vein isolation (CPVI) combined with substrate ablation after valvular surgery and the concomitant Maze procedure for the treatment of AF in patients with rheumatic heart disease (RHD). The aim of this stu...
متن کاملLate outcome of surgical radiofrequency ablation for persistent valvular atrial fibrillation in China: a single-center study
BACKGROUND Atrial fibrillation (AF) adversely affects surgical outcomes of cardiac valve surgery. Surgical ablation is an effective way to treat valvular AF. The aim of this study was to evaluate the late outcome of surgical radiofrequency ablation and explore the risk factors of AF recurrence in Chinese patients undergoing cardiac valve surgery. METHODS Three hundred ninety six consecutive p...
متن کاملIllustrated techniques for performing the Cox-Maze IV procedure through a right mini-thoracotomy.
The Cox-Maze IV procedure has replaced the "cut-and-sew" technique of the original Cox-Maze operation with lines of ablation created using bipolar radiofrequency (RF) and cryothermal energy devices. In select patients, this procedure can be performed through a right mini-thoracotomy. This illustrated review is the first to detail the complete steps of the Cox-Maze IV procedure performed through...
متن کامل