Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods
نویسندگان
چکیده
The accurate duplicate cast obtained from a single impression reduces the profession clinical time, patient inconvenience, and extra material cost. The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with five mm spacer and two mm spacer. The impression methods evaluated during the study were additional silicone putty reline (two steps), heavy-light body (one step), monophase (one step), and polyether (one step). Type IV gypsum casts were poured at the interval of one hour, 12 hours, 24 hours, and 48 hours. The resultant cast was measured with traveling microscope for the comparative dimensional accuracy. The data obtained were subjected to Analysis of Variance test at significance level <0.05. The die obtained from two-step putty reline impression techniques had the percentage of variation for the height -0.36 to -0.97%, while diameter was increased by 0.40-0.90%. The values for one-step heavy-light body impression dies, additional silicone monophase impressions, and polyether were -0.73 to -1.21%, -1.34%, and -1.46% for the height and 0.50-0.80%, 1.20%, and -1.30% for the width, respectively.
منابع مشابه
A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique
A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique Dr. M. Farzin *- Dr. F. Bahrani ** - Dr. A. Zareie *** *Assistant Professor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences. **Clinical Instructor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences....
متن کاملElastomeric impression materials: a comparison of accuracy of multiple pours.
AIM The aim of the present study is to compare the various elastomeric impression materials in terms of accuracy and dimensional stability, with respect to obtaining multiple casts from a single elastomeric impression at various times of pours. MATERIALS AND METHODS Three master dies were prepared for the impression making, two of these were made of brass containing a central hole with underc...
متن کاملA New Hybrid Technique for Beading and Boxing of Complete Denture Final Impressions
Introduction: The purpose of beading & boxing of an impression is to obtain an accurate cast with proper border & base thickness for fabrication of restorations. Beading is the protection of the formed border thickness of the final impressions & Boxing of an impression is building up vertical walls around it. Aim: The purpose of this hybrid technique of beading and boxing is to produce a smooth...
متن کاملDimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...
متن کاملComparison of accuracy and reproducibility of casts made by digital and conventional methods.
STATEMENT OF PROBLEM Little peer-reviewed information is available regarding the accuracy and reproducibility of digitally fabricated casts compared to conventional nondigital methods. PURPOSE The purpose of this in vitro study was to compare the accuracy and reproducibility of a digital impression and cast fabrication with a conventional impression and cast fabrication. MATERIAL AND METHOD...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016