Morphologic and biomechanical comparison of spinous processes and ligaments from scoliotic and kyphotic patients.

نویسندگان

  • Brian P Beaubien
  • Andrew L Freeman
  • Glenn R Buttermann
چکیده

The spinous processes and supraspinous and interspinous ligaments (SSL and ISL, respectively) limit flexion and may relate to spinal curvature. Spinous process angles and mechanical properties of explanted human thoracic posterior SSL/ISL complexes were compared for scoliosis (n=14) vs. kyphosis (n=8) patients. The median thoracic coronal Cobb angle for scoliosis patients was 48°, and sagittal angles for kyphosis patients was 78°. Spinous processes were gripped and four strain steps of 4% were applied and held. Percent relaxation was calculated over each step, equilibrium load data were fit to an exponential equation, and a Kelvin model was fit to the load from all four curves. Failure testing was also performed. Median ligament complex dimensions from scoliosis and kyphosis patients were, respectively: ISL width=16.5mm and 16.0mm; SSL width=4.3mm and 3.8mm; ISL+SSL area=17.2mm and 25.7mm; these differences were not significant. Significant differences did exist in terms of spinous process angle vs. spine axis (47° for scoliosis and 32° for kyphosis) and SSL thickness (2.1mm for scoliosis and 3.0mm for kyphosis). Fourth-step median relaxation was 42% for scoliosis and 49% for kyphosis. Median linear region stiffness was 42N/mm for scoliosis and 51N/mm for kyphosis. Median failure load was 191N for scoliotic and 175N for kyphotic ligaments. Differences in loading, relaxation, viscoelastic and failure parameters were not statistically significant, except for a trend for greater initial rate of relaxation (T1) for scoliosis ligaments. However, we found significant morphological differences related to the spinous processes, which suggests a need for future biomechanical studies related to the musculoskeletal aspects of spinal alignment and posture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interspinous Process Implants Causes Wear of the Spinous Processes in Patients Treated for Spinal Stenosis—An Experimental Biomechanical Study with Comparison to Clinical Cases

There are few biomechanical studies on Interspinous Process Implants (IPD); however none investigate the amount of wear on spinous processes. Therefore the objective of the present study was to investigate the effect of repetitive loading of the IPD Aperius on the spinous processes in a biomechanical porcine model. For comparison, three patients treated surgically with the same device have been...

متن کامل

Anatomy of Lumbar Interspinous Ligaments: Attachment, Thickness, Fibre Orientation and Biomechanical Importance

Literature related to the study of interspinous ligament in the lumbar region is sparse. Very few studies have elucidated the fibre orientation of this ligament at different lumbar levels. Male (19) and female (6) cadavers were dissected to expose the interspinous ligaments beneath all the lumbar vertebrae. Fibre attachments and directions were observed at all lumbar interspinous spaces. Thickn...

متن کامل

Posterior vertebral arch cement augmentation (spinoplasty) to prevent fracture of spinous processes after interspinous spacer implant.

BACKGROUND AND PURPOSE Interspinous spacers are implanted to treat symptomatic lumbar stenosis. Posterior vertebral element fractures can occur during or after interspinous spacer implants, especially in patients with osteopenia. The purpose of our study was to assess the biomechanical rationale, safety, feasibility, and effectiveness of posterior vertebral arch cement augmentation (spinoplasty...

متن کامل

Biomechanics of Degenerative Spinal Disorders.

The spine has several important functions including load transmission, permission of limited motion, and protection of the spinal cord. The vertebrae form functional spinal units, which represent the smallest segment that has characteristics of the entire spinal column. Discs and paired facet joints within each functional unit form a three-joint complex between which loads are transmitted. Surr...

متن کامل

Stability of the human spine: a biomechanical study.

The influences of curvatures and of physical properties on the mechanical stability of the spine were analysed by means of a three-dimensional, geometrical, nonlinear biomechanical model. According to the model, the initial buckling load decreases with increasing lordotic and kyphotic curvatures. When the body weight is taken into account as a load distributed along the whole spine, the calcula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 49 2  شماره 

صفحات  -

تاریخ انتشار 2016