Numerical Evaluation of an 8-element Phased Array Torso Coil for Magnetic Resonance Imaging

نویسندگان

  • Feng Liu
  • Joe Li
  • Ian Gregg
  • Nick Shuley
  • Stuart Crozier
چکیده

Recently, parallel imaging using multiple RF coils has excited great interest in magnetic resonance imaging (MRI). To help the design of some novel flexible array coils for the human torso, we theoretically investigate the RF field of an 8-element array coil loaded with an anatomically accurate model of the human torso. The RF behaviour is predicted based on a hybrid FDTD/MoM approach. The primary results are reported and simulations demonstrate the feasibility of torso imaging using array coils.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiofrequency Coil Array Design and Optimisation for Magnetic Resonance Low Field Imaging

Radiofrequency (RF) coil phased arrays are getting more and more important for accelerating the imaging speed and for gaining better signal to noise ratio (SNR) in magnetic resonance imaging (MRI). The approach is conceptually similar to phased array used in radar techniques hence it is used to be called MRI phased array coils. To get maximum benefits from this technique, coil and preamp decoup...

متن کامل

Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer

PURPOSE Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil ...

متن کامل

Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil.

PURPOSE To improve the homogeneity of transmit volume coils at high magnetic fields (> or =4 T). Due to radiofrequency (RF) field/tissue interactions at high fields, 4 T to 8 T, the transmit profile from head-sized volume coils shows a distinctive pattern with relatively strong RF magnetic field B(1) in the center of the brain. MATERIALS AND METHODS In contrast to conventional volume coils at...

متن کامل

Use of phased array coils for a determination of absolute metabolite concentrations.

This work describes the use of phased array coils for a quantification of absolute metabolite concentrations. The method is demonstrated for single-voxel localized proton MRS of human brain with an eight-element receive-only head coil. It is based on the transmitter reference amplitude of the body coil used for RF transmission. A relative sensitivity of every element of the phased array coil is...

متن کامل

MR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils

Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003