Comparative analysis of 2 resonance frequency measurement devices: Osstell Mentor and Osstell ISQ.
نویسندگان
چکیده
OBJECTIVE Comparing reliability of Osstell Mentor and Osstell ISQ in implant stability measurement, and assessing whether their measurements are comparable. MATERIALS AND METHOD Implant stability was measured with both devices on 58 implants in 15 patients. Six measurements were completed with each device with 2 different transducers (3 measurements with each transducer), that is, 12 measurements for each implant. RESULTS Mean implant stability quotient (ISQ) value with Osstell ISQ was 72.59, 72.47, and 73.17 in the first measurements, respectively. With Osstell Mentor, the results were 72.43, 72.60, and 73.26, respectively; mean ranges were 3.37, 3.60, and 3.75, respectively. However, mean value with Osstell ISQ and Osstell Mentor was 72.87 and 72.04, respectively. The intraclass correlation coefficient was 0.98. This means an almost perfect degree of concordance between both devices. CONCLUSIONS Resonance frequency analysis systems in Osstell Mentor and Osstell ISQ show almost perfect reproducibility and repeatability.
منابع مشابه
A comparative study on the accuracy of the devices for measuring the implant stability
STATEMENT OF PROBLEM How the ISQ values measured by Osstell™ and Osstell™ Mentor are related, and whether the ISQ values acquired from the two machines changes in accordance with changes in implant stability are not yet fully understood. PURPOSE The aim of this study was to find out correlation between the ISQ values acquired from Osstell™ and Osstell™ Mentor, and to evaluate the clinical eff...
متن کاملISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
BACKGROUND Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. The influence of the latter on the overall measurement results is presently unknown. It can be inve...
متن کاملResonance frequency analysis-reliability in third generation instruments: Osstell mentor®
UNLABELLED Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). OBJECTIVE Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the ...
متن کاملAssessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study
UNLABELLED Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. OBJECTIVE Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) ...
متن کاملA novel device for resonance frequency assessment of one-piece implants.
PURPOSE Immediate loading and/or restoration of dental implants requires the assessment of implant stability, which is best performed by resonance frequency analysis (RFA) prior to loading. One-piece dental implants are usually used for immediate loading, but there is currently no available reliable method to assess the primary stability of one-piece dental implants. Therefore, this study sough...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Implant dentistry
دوره 23 3 شماره
صفحات -
تاریخ انتشار 2014