Coupling of Voltage-Sensors to the Channel Pore: A Comparative View
نویسندگان
چکیده
The activation of voltage-dependent ion channels is initiated by potential-induced conformational rearrangements in the voltage-sensor domains that propagates to the pore domain (PD) and finally opens the ion conduction pathway. In potassium channels voltage-sensors are covalently linked to the pore via S4-S5 linkers at the cytoplasmic site of the PD. Transformation of membrane electric energy into the mechanical work required for the opening or closing of the channel pore is achieved through an electromechanical coupling mechanism, which involves local interaction between residues in S4-S5 linker and pore-forming alpha helices. In this review we discuss present knowledge and open questions related to the electromechanical coupling mechanism in most intensively studied voltage-gated Shaker potassium channel and compare structure-functional aspects of coupling with those observed in distantly related ion channels. We focus particularly on the role of electromechanical coupling in modulation of the constitutive conductance of ion channels.
منابع مشابه
Multiple pore conformations driven by asynchronous movements of voltage sensors in a eukaryotic sodium channel
Voltage-dependent Na(+) channels are crucial for electrical signalling in excitable cells. Membrane depolarization initiates asynchronous movements in four non-identical voltage-sensing domains of the Na(+) channel. It remains unclear to what extent this structural asymmetry influences pore gating as compared with outwardly rectifying K(+) channels, where channel opening results from a final co...
متن کاملDeletion of cytosolic gating ring decreases gate and voltage sensor coupling in BK channels
Large conductance Ca2+-activated K+ channels (BK channels) gate open in response to both membrane voltage and intracellular Ca2+ The channel is formed by a central pore-gate domain (PGD), which spans the membrane, plus transmembrane voltage sensors and a cytoplasmic gating ring that acts as a Ca2+ sensor. How these voltage and Ca2+ sensors influence the common activation gate, and interact with...
متن کاملEnergetics of Pore Opening in a Voltage-Gated K+ Channel
Voltage-dependent gating in K(+) channels results from the mechanical coupling of voltage sensor movements to pore opening. We used single and double mutations in the pore of the Shaker K(+) channel to analyze a late concerted pore opening transition and interpreted the results in the context of known K(+) channel structures. Gating sensitive mutations are located at mechanistically informative...
متن کاملMode shift of the voltage sensors in Shaker K+ channels is caused by energetic coupling to the pore domain
The voltage sensors of voltage-gated ion channels undergo a conformational change upon depolarization of the membrane that leads to pore opening. This conformational change can be measured as gating currents and is thought to be transferred to the pore domain via an annealing of the covalent link between voltage sensor and pore (S4-S5 linker) and the C terminus of the pore domain (S6). Upon pro...
متن کاملGating transitions in the selectivity filter region of a sodium channel are coupled to the domain IV voltage sensor.
Voltage-dependent ion channels are crucial for generation and propagation of electrical activity in biological systems. The primary mechanism for voltage transduction in these proteins involves the movement of a voltage-sensing domain (D), which opens a gate located on the cytoplasmic side. A distinct conformational change in the selectivity filter near the extracellular side has been implicate...
متن کامل