Evaluation of newly developed veterinary portable blood glucose meter with hematocrit correction in dogs and cats

نویسندگان

  • Akihiro MORI
  • Hitomi ODA
  • Eri ONOZAWA
  • Saori SHONO
  • Toshinori SAKO
چکیده

This study evaluated the accuracy of a newly developed veterinary portable blood glucose meter (PBGM) with hematocrit correction in dogs and cats. Sixty-one dogs and 31 cats were used for the current study. Blood samples were obtained from each dog and cat one to six times. Acceptable results were obtained in error grid analysis between PBGM and reference method values (glucose oxidation methods) in both dogs and cats. Bland-Altman plot analysis revealed a mean difference between the PBGM value and reference method value of -1.975 mg/dl (bias) in dogs and 1.339 mg/dl (bias) in cats. Hematocrit values did not affect the results of the veterinary PBGM. Therefore, this veterinary PBGM is clinically useful in dogs and cats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Evaluation of a continuous glucose monitoring system for use in dogs, cats, and horses.

OBJECTIVE To evaluate a continuous glucose monitoring system (CGMS) for use in dogs, cats, and horses. DESIGN Prospective clinical study. Animals-7 horses, 3 cats, and 4 dogs that were clinically normal and 1 horse, 2 cats, and 3 dogs with diabetes mellitus. PROCEDURE Interstitial glucose concentrations were monitored and recorded every 5 minutes by use of a CGMS. Interstitial glucose conce...

متن کامل

Cumulative Clinical Evaluation of Transcutaneous Blood Laser Irradiation on Hemodynamic Changes in Anesthesia of Dogs

Objectives-The aims of this study were evaluation the effects of blood laser irradiation on hemodynamic parameters, the amount of anesthetic drugs in maintenance of anesthesia and duration of recovery. Animals- Fifteen mixed breed dogs Procedures- dogs (25.0 ± 3.6 kg) were divided into three groups (n=5). The group I was acted as control and received only cold laser. The group II was premedicat...

متن کامل

Volumetric evaluation of pituitary gland in dog and cat using computed tomography

The objective of this study was to evaluate the pituitary gland dimensions due to age and weight using computed tomography (CT) in dogs and cats. The CT images of pituitary gland were assessed in 11 client-owned dogs (six males and five females; age range, 1 to 9 years) and 15 client-owned cats (eight males and seven females; age range, 1 to 14 years) with no evidence of pituitary diseases. The...

متن کامل

Evaluation of thoracic trauma in dogs and cats: a review of seventeen cases

The objective of this study was to assess the etiology, diagnosis, treatment methods, surgical findings, postoperative results and necropsy findings of seventeencases of thoracic traumaby evaluating medical records. A car accident, falling down, stabbing and bites were identified asthe causes of trauma. Diagnosed pathologies in the cases included pneumothorax, hemothorax, pulmonary contusion, l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 79  شماره 

صفحات  -

تاریخ انتشار 2017