PURPOSE The purpose of this study was to compare postoperative range of motion and functional outcomes among patients who received high-flexion total knee arthroplasty using cruciate-retaining (CR-Flex) and posterior-stabilized (PS-Flex) type prostheses. MATERIALS AND METHODS Among 127 patients (186 knees) who underwent high-flexion total knee arthroplasty between 2005 and 2007, 92 knees were placed in the CR-Flex group, and 94 knees were placed in the PS-Flex group. After two years of postoperative follow-up, clinical and radiographic data were reviewed. Postoperative non-weight-bearing range of knee motion, angle of flexion contracture and functional outcomes based on the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) functional sub-scale were assessed and compared between the two groups. RESULTS After the 2-year postoperative period, the mean range of motion was 131° in the CR-Flex group and 133° in the PS-Flex group. There were no significant differences in postoperative range of motion between the two groups. Only age at operation and preoperative range of motion were significantly associated with postoperative range of motion after high-flexion total knee arthroplasty. Postoperative functional outcomes based on the WOMAC functional sub-scale were slightly better in the CR-Flex group (9.2±9.1 points) than in the PS-Flex group (11.9±9.6 points); however, this difference was not statistically significant (p=non-significant). CONCLUSION The retention or substitution of the posterior cruciate ligament does not affect postoperative range of motion (ROM) or functional outcomes, according to 2 years of postoperative follow-up of high-flexion total knee arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does High-flexion Design of Cruciate Retaining Total Knee Prosthesis Increase Postoperative Range of Motion?

INTRODUCTION: The range of motion (ROM) after total knee arthroplasty (TKA) is one of the most important factors for patient satisfaction, especially in Asian countries. To enhance the knee flexion angle, “highflexion” designs have been introduced in total knee prostheses. One of such design was a new design of femoral prosthesis, which increased the posterior cut on the bone by 2 mm and thicke...

متن کامل

Biomechanics of Hyperflexion and Kneeling before and after Total Knee Arthroplasty

The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact...

متن کامل

Outcomes of the Different Types of Total Knee Arthroplasty with the Identical Femoral Geometry

PURPOSE There are controversies around the role of the posterior cruciate ligament and the effect of design modifications for high flexion in total knee arthroplasty (TKA). So, we compared the clinical outcomes of the cruciate retaining (CR), posterior stabilized (PS), and high flexion posterior stabilized (F-PS) designs in TKA with identical femoral geometry. MATERIALS AND METHODS One hundre...

متن کامل

Comparison of outcomes after bilateral simultaneous total knee arthroplasty using posterior-substituting versus cruciate-retaining prostheses

OBJECTIVES To compare the effectiveness and safety of posterior-substituting (PS) with cruciate-retaining (CR) total knee prostheses after the elimination of confounding variables. METHODS Between January 2008 and June 2012, a total of 32 subjects who had bilateral arthritis of the knees agreed to have one knee replaced with a PS total knee design and the other with a CR design. In addition t...

متن کامل

Total knee arthroplasty in patients with greater than 20 degrees flexion contracture.

Fixed flexion contracture can present a technical challenge in total knee arthroplasty. Various techniques of addressing these deformities have been described including additional bony resection, ligamentous releases, and the use of increasing constraint. We retrospectively reviewed the clinical outcomes of 40 patients (52 knees) with fixed flexion contracture greater than or equal to 20 degree...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 53  شماره 

صفحات  -

تاریخ انتشار 2012