Computational simulations of the influence of angular rotation deviations in optical CT imaging of gel dosimeters
نویسندگان
چکیده
Two types of angular rotation deviations are observed in our optical CT scanner for gel dosimetry: a large deviation at the starting position, and small deviations during the scanning. In order to investigate the influence of these angular rotation deviations on the reconstructed OD maps, we applied the angular deviations on a synthetic phantom for optical CT simulation. Meanwhile, three reconstruction schemes are proposed for compensation. The simulation results show that the influence of both types of rotation deviation is as small as less than 1% over the central reconstruction phantom region. Based on the reconstructed results via different methods, we can conclude: 1) reconstruction with the regridded projections can better decrease the errors caused by the large angle deviation; 2) for small angle deviations, reconstruction with actual-angle compensation delivers less pronounced results; 3) for real cases, the hybrid approach is shown to reduce reconstruction errors.
منابع مشابه
Designing and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملComparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry
Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملBrachytherapy polymer gel dosimetry with xCT
ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کامل