Effect of intraocular lens insertion speed on surgical wound structure.
نویسنده
چکیده
PURPOSE To evaluate the difference in the effect of 2 speeds of intraocular lens (IOL) insertion on the clear corneal wound structure. SETTING Ouchi Eye Clinic, Kyoto, Japan. DESIGN Prospective randomized clinical trial. METHOD Eyes that had phacoemulsification and Acrysof IQ IOL implantation using a screw-plunger type injector were randomly divided into 2 equally sized groups as follows: Group F, fast IOL insertion (1 revolution per second [rps]) plunger speed, and Group S, slow IOL insertion (¼ rps). The change in wound-size between before IOL insertion and after IOL insertion, need for corneal hydration, surgically induced astigmatism (SIA), and optical coherence tomography (OCT) findings of the corneal wound structure were compared. Comparative laboratory measurements of the cross-sectional surface between empty cartridges and those with an IOL loaded inside were also performed. RESULTS Eighty eyes were enrolled. The change in wound size was significantly larger in Group S (P=.002). Corneal hydration was required in 11 of 40 eyes in Group F and in 21 of 40 eyes in Group S (P=.04). Changes in OCT findings were also more prominent in Group S (P=.003). There were no significant differences in SIA. Laboratory examination of the cartridges showed that the vertical diameter of the cross-sectional area was significantly larger when the IOL was loaded than when the cartridge was empty. CONCLUSION When an injector system was used, slow IOL insertion affected clear corneal wound structure more than fast IOL insertion.
منابع مشابه
Hydro-visco-implantation Technique for Wound-assisted Foldable Intraocular Lens Implantation During Microincision Cataract Surgery
We have described a hydro-visco-implantation technique (simultaneous use of sodium hyaluronate and balanced salt solution) for wound-assisted intraocular lens (IOL) implantation and passive removal of ophthalmic viscosurgical device (OVD). In the technique, the capsular bag was filled approximately up to half with OVD, and anterior chamber was formed by bimanual irrigation cannula with continuo...
متن کاملInsertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
BACKGROUND The use of conventional foldable hydrophobic intraocular lenses (IOLs) in microincision cataract surgery (MICS) currently requires wound enlargement. We describe a combined surgical technique of MICS and trabeculectomy with insertion of a foldable IOL through the trabeculectomy fistula. METHODS After completion of MICS through two side port incisions, a 3.2 mm keratome is used to e...
متن کاملLens vacuoles during phakic intraocular lens implantation
Lens damage during phakic intraocular lens implantation is a major complication. A case of a patient who developed lens vacuoles during toric implantable collamer lens (ICL) removal from her right eye and insertion of a new non-toric ICL due to persistent rotation of the former is presented in this work. As this event is very uncommon when implanting phakic intraocular lenses, the performed sur...
متن کاملTreatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation
The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...
متن کاملAir-assisted Descemet-stripping automated endothelial keratoplasty with posterior chamber iris-fixation of aphakic iris-claw intraocular lens.
We report a combination of surgical techniques during Descemet-stripping automated endoithelial keratoplasty and intraocular lens (IOL) exchange in patients with pseudophakic bullous keratopathy and angle-supported anterior chamber IOLs. During this procedure, the anterior chamber IOL is exchanged for a posterior chamber iris-claw IOL enclavated to the posterior iris; the anterior chamber is ke...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 38 10 شماره
صفحات -
تاریخ انتشار 2012