An organic hydrogel film with micron-sized pillar array for real-time and indicator-free detection of Zn2+

نویسندگان

  • Yu-Chiang Chao
  • Yi-Sa Huang
  • Hsin-Ping Wang
  • Ssu-Ming Fu
  • Chien-Hao Huang
  • Yen-Chun Liang
  • Wen-Cheng Yang
  • Yu-Sheng Huang
  • Gao-Fong Chang
  • Hsiao-Wen Zan
  • Hsin-Fei Meng
  • Chen-Hsiung Hung
  • Chien-Chung Fu
چکیده

A hydrogel sensing film for a real-time and indicator-free detection of Zn is developed by embedding a fluorescent indicator 11,16-bis(phenyl)-6,6,21,21-tetramethyl-m-benzi-6,21porphodimethene in a hydrogel host poly(2-hydroxyethyl methacrylate). The sensing film shows high stability and selectivity to Zn. The sensitivity of the sensing film is increased by fabricating a micron-sized pillar array on the surface of the sensing film to increase the surface area. For Zn concentrations of 10 4 and 10 3 M, the response time is 30 and 3 s, respectively. 2011 Elsevier B.V. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-Cost Photolithographic Fabrication of Nanowires and Microfilters for Advanced Bioassay Devices

Integrated microfluidic devices with nanosized array electrodes and microfiltration capabilities can greatly increase sensitivity and enhance automation in immunoassay devices. In this contribution, we utilize the edge-patterning method of thin aluminum (Al) films in order to form nano- to micron-sized gaps. Evaporation of high work-function metals (i.e., Au, Ag, etc.) on these gaps, followed b...

متن کامل

Immobilization of lipase B within micron-sized poly-N-isopropylacrylamide hydrogel particles by solvent exchange.

The aim of the present work is the use of a water soluble enzyme in an organic solvent, still with a pronounced catalytic activity. Therefore, lipase B from Candida antarctica (CalB) is immobilized within micron-sized thermosensitive p-NIPAM hydrogel particles using a solvent exchange from polar to organic solvents. The absorbed amount of CalB is investigated at different immobilization tempera...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

An Investigation on Two Types of Crystalline Micro-diamond Film Coated Tools Lapping with Sapphire Wafer

Two types of micron-diamond films were prepared on YG6 substrate by hot filament chemical vapor deposition(HFCVD) method. Morphology and orientation of crystalline growth were evaluated by SEM and XRD. Diamond film coated tools and sapphire wafer’ surface before and after lapping experiment  were contrasted. The results indicated that a significant change in Raman spectrum of two types of micro...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -