Towards narrower analytical goals in routine laboratory work.
نویسندگان
چکیده
596 CLINICAL CHEMISTRY, Vol. 37, No. 4, 1991 1. Howanitz PJ, Howanitz JH, Lamberson HV, Ennis KM. Incidence and mechanism of spurious increases in serum thyrotropin. Clin Chem 1982;28:427-31. 2. Boscato LM, Stuart MC. Incidence and specificity of interference in two-site inununoassays. Clin Chem 1986;32:1491-5. 3. Boscato LM, Stuart MC. Heterophilic antibodies: a problem for all immunoassays. Clin Chem 1988;34:27-33. 4. Kahn BB, Weintraub BD, Csako G, Zweig MH. Factitious elevation of thyrotropin in a new ultrasensitive assay: implications for the use of monoclonal antibodies in “sandwich” immunoassay. J Clin Endocrinol Metab 1988;66:526-33. 5. Zweig MH, Csako G, Spero M. Escape from blockade of interfering heterophile antibodies in a two-site immunoradiometnc assay for thyrotropin. Clin Chem 1988;34:2589-91. 6. Skovsted L, Hansen JM. Falsely raised serum thyrotropin with modified imnumoradiometnic assay [Letter]. Lancet 1988; i:359. 7. Harvey RD, McHardy KC, Trainer PJ, Reid I. Interference in modified immunoradiometnic assay for thyrotropin [Letter]. Lancet 1988;i:716. 8. Zweig MH, Csako G, Benson CC, Weintraub BD, Kahn BB. Interference by antiimmunoglobulin G antibodies in immunoradiometric assays of thyrotropin involving mouse monoclonal antibodies. Clin Chem 1987;33:840-4.
منابع مشابه
Assessment of the Trueness and Inter-Laboratory Precision of Routine Uric Acid Assays Using 4 Frozen Pooled Serum Samples Measured by the Japan Society of Clinical Chemistry's HPLC Method
BACKGROUND Reference procedures are required for evaluating the accuracy of routine analytical systems for uric acid (UA). External quality assessment (EQA) for UA has only been conducted with quality controls in China, and the results have not been published. This study was designed to investigate both the trueness and inter-laboratory precision of UA measurements among routine analytical syst...
متن کاملCholesterol operational process specifications for assuring the quality required by CLIA proficiency testing.
Current U.S. governmental regulations and requirements for the quality of laboratory tests do not provide a consistent form, comparable numbers, or practical specifications for the routine operation of laboratory testing processes. For cholesterol, as an example, the Health Care Financing Administration provides an analytical performance criterion for proficiency testing to enforce the Clinical...
متن کاملAnalytical Goals for Point-of-Care Testing Used for Diabetes Management in Australian Health Care Settings Outside The Laboratory
Diabetes mellitus is a major global health problem. Pathology testing for hemoglobin A1c (HbA1c), lipids, and urine albumin/creatinine ratio (ACR) has an important role in the management of diabetes patients. Each of these markers can be performed by point-of-care testing (POCT). This article focuses on setting analytical goals (quality specifications) for the imprecision, bias, and total allow...
متن کاملA routine method for the quantification of the novel antimycotic drug posaconazole in plasma using liquid chromatography-tandem mass spectrometry.
BACKGROUND Posaconazole is now widely used for prophylaxis of invasive fungal infections in immunocompromised patients. The pharmacokinetic properties of the drug argue for therapeutic monitoring, but so far described analytical methods have shortcomings with respect to application in a routine setting. The aim of our work was to develop an analytical method suitable for routine use. METHODS ...
متن کاملGovernmental perspectives on evaluating laboratory performance.
The quality of laboratory analytical performance required to support medical decision-making has been defined in four major ways: (a) by the analytical variance of the state of the practice; (b) by the total variance, including analytical and biological variability; (c) by the loss of diagnostic efficiency attributable to analytical error; and (d) by medical-usefulness criteria. From the federa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 37 4 شماره
صفحات -
تاریخ انتشار 1991