Physiological identification of variation sources of transthoracic electrical impedance during breath holding.

نویسنده

  • Y Hukushima
چکیده

Variations of transthoracic electrical impedance and their relations with physiological events within the thorax were studied by using electrodes applying constant sinusoidal current at 55kHz on bilateral chest walls of anesthetized dogs during breath holding. The level of the impedance lowered during decrease of oxygen and elevated during ether gas evaporation in the lungs with steady pulmonary blood flow. The impedance decreased when concentrated saline was selectively infused into the pulmonary vasculature but not into the left heart and the great vessels. The impedance levels also were related inversely with the change of blood flow and resultant blood volume in the lung when the pulmonary blood flow was decreased as during occlusion of the venous return to the right heart, pulmonary trunk and unilateral pulmonary artery. The impedance levels on the bilateral chest walls varied independently by manipulations mentioned above which was employed in the individual lung of each hemithorax. These results clearly suggest that the current flux applied on the chest wall well penetrates through the chest cage and passes preferentially through the lung parenchyma, the conductivity of which depends on the changes in the amount of electrically conductive or resistive materials associated with physiological events within the lungs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.

1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...

متن کامل

Variations of transthoracic electrical impedance in relation with hemodynamic changes of pulmonary circulation.

Applying electrodes on bilateral chest walls, variations of electrical impedance were recorded during breath holding under various manipulations of the pulmonary hemodynamics with dogs. Pulsatile variations of the impedance recorded either directly from lobe surfaces or chest walls were in constant coupling with ECG and pressure waves in the pulmonary artery. These impedance pulses and their fi...

متن کامل

Fast EIT data acquisition system with active electrodes and its application to cardiac imaging.

A wide-band high-speed data acquisition system for electrical impedance tomography (EIT) is described. 32 active electrodes are used in the system, half of them as receive electrodes and the other half as drive electrodes. A buffer is mounted on the back of each receive electrode and a current source on each drive electrode. A multielectrode system with active electrodes was built to make it co...

متن کامل

Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General Anaesthesia

This study evaluated the breathing pattern and distribution of ventilation in horses prior to and following recovery from general anaesthesia using electrical impedance tomography (EIT). Six horses were anaesthetised for 6 hours in dorsal recumbency. Arterial blood gas and EIT measurements were performed 24 hours before (baseline) and 1, 2, 3, 4, 5 and 6 hours after horses stood following anaes...

متن کامل

A Comparison of the Physiological Responses to Underwater Arm Cranking and Breath Holding Between Synchronized Swimmers and Breath Holding Untrained Women

Exercise and breath holding in the water such as that performed in the sport of synchronized swimming may evoke the physiological consequences of the diving response. The purpose of this study was to investigate the physiological responses of breath holding during underwater arm cranking in synchronized swimmers who are trained in breath holding and compare these responses to untrained women. E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese heart journal

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 1970