Comparison of Diafiltration and Tangential Flow Filtration for Purification
نویسندگان
چکیده
Purpose. The study reports evaluation of different purification processes for removing surplus surfactant and formulating stable nanoparticle dispersions. Methods. Nanoparticle formulations prepared from poly(D,L-lactide-co-glycolide) and polyvinyl alcohol (PVA) were purified by a diafiltration centrifugal device (DCD), using 300K and 100K molecular weight cut-off (MWCO) membranes and a tangential flow filtration (TFF) system with a 300K MWCO membrane. The effects of process parameters including MWCO, transmembrane pressure (TMP), and mode of TFF on nanoparticle purification were evaluated, and two purification techniques were compared to the commonly used ultracentrifugation technique. Results. Both DCD and TFF systems (concentration mode at TMP of 10 psi) with 300K MWCO membrane removed maximal percent PVA from nanoparticle dispersions (89.0 and 90.7%, respectively). T90, the time taken to remove 90% of PVA in 200-ml sample, however, was considerably different (9.6 and 2.8 h, respectively). Purified nanoparticle dispersions were stable and free of aggregation at ambient conditions over 3 days. This is in contrast to the ultracentrifugation technique, which, although it can yield a highly purified sample, suffers from drawbacks of a level of irreversible nanoparticle aggregation and loss of fine particles in the supernatant during centrifugation. Conclusions. The TFF, in concentration mode at TMP of 10 psi, is a relatively quick, efficient, and costeffective technique for purification and concentration of a large nanoparticle batch (Q 200 ml). The DCD technique can be an alternative purification method for nanoparticle dispersions of small volumes.
منابع مشابه
Protein Concentration and Diafiltration by Tangential Flow Filtration
PURPOSE Membrane-based Tangential Flow Filtration (TFF) unit operations are used for clarifying, concentrating, and purifying proteins. This technical brief is a practical introduction to protein processing using tangential flow filtration. It is intended to help scientists and engineers achieve their protein processing objectives by discussing how the choice of key components and operating par...
متن کاملDiafiltration (Buffer Exchange) Using Hollow Fiber Membranes instead of Dialysis Tubing - Automated Diafiltration
Diafiltration is term used reflecting tangential flow filtration (TFF) method of “washing” or removing a permeable molecule (impurities, salts, solvents, small proteins, etc) from a solution in an accelerated method when compared to dialysis tubing. By selecting the appropriate membrane(s), it can also be used to exchange buffers, narrow particle size distributions, modify salt concentrations o...
متن کاملUse of the labscale tangential flow diafiltrator to remove tetrameric hemoglobin from polyhemoglobin, purify hemolysate, and concentrate polyhemoglobin.
The Labscale tangential flow diafiltration system in conjunction with polyethersulfone Biomax filters (both purchased from Millipore Inc.) were used in the following studies: (1) A crucial step in the preparation of polyhemoglobin (polyHb) is the removal of tetrameric hemoglobin (Hb), which can cause adverse side-effects. The efficiency for this depends on the integrity of the 100kDa filters. T...
متن کاملComparison of two gel filtration chromatography resins for the purification of foot-and-mouth disease virus as a purified vaccine antigen
Introduction: Foot-and-mouth disease (FMD) is a highly contagious and economically devastating viral disease of livestock that is categorized in list A of animal diseases by the World Organisation for Animal Health (OIE). Vaccination is effective against FMD and the vaccine production centers largely use the industrial ultra-filtration and chromatography in order to remove the cellular proteins...