Simulated effects of head movement on contact pressures between headforms and N95 filtering facepiece respirators part 2: simulation.

نویسندگان

  • Zhipeng Lei
  • Xuewu Ji
  • Ning Li
  • James Yang
  • Ziqing Zhuang
  • Dana Rottach
چکیده

Finite element (FE) filtering facepiece respirators (FFRs) were developed and mated to the new headforms with a cervical spine model. The FFRs from three manufacturers included three sizing systems: (i) a single one-size-fits all, (ii) an FFR with two sizes (S/M and M/L), and (iii) an FFR with three sizes (S, L/M, XL). Finite element method (FEM) simulations of 16 headform and respirator combinations (5 headforms and 6 respirators) were used to examine maximum contact pressure changes for five cases: static head, flexion, extension, left rotation, and right rotation. For each of the 16 headform and respirator combinations, maximum contact pressures of the static headform and motile headforms were compared using t-tests. Significant differences on the maximum contact pressures were found in the extension, left rotation and right rotation at the nose (P < 0.005), the left rotation at the top of right cheek (P = 0.03), and the extension at the bottom of left/right cheek (P = 0.01). When separately considering each headform and each FFR manufacturer, the effects of the four head movement cases on the nose maximum contact pressure changes were observed in the simulations with all five headforms and all FFR manufacturers. The effects of the left and right rotations on the chin maximum contact pressure changes were observed in the simulations with the small headform. It was also found that the use of a nose clip could reduce the impact of the head left/right rotations on nose maximum contact pressure changes. In addition, head movements changed pressure contours of the key nose area. Caused by the head movements, the maximum contact pressure changes may affect seal quality, and the increase of the maximum contact pressures could reduce the facial comfort level.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Headform and N95 filtering facepiece respirator interaction: contact pressure simulation and validation.

This article presents a computational and experimental study of contact pressure between six N95 filtering facepiece respirators (FFRs) and five newly developed digital headforms (small, medium, large, long/narrow, and short/wide). Contact interaction is simulated using the finite element method and validated by experiments using a pressure mapping system. The headform model has multiple layers...

متن کامل

Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.

A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...

متن کامل

Comparison of Simulated Workplace Protection Factors Offered by N95 and P100 Filtering Facepiece and Elastomeric Half-Mask Respirators against Particles of 10 to 400 nm

This study compared the simulated workplace protection factors (SWPFs) between NIOSH-approved N95 respirators and P100 respirators, including two models of filtering facepiece respirator (FFR) and two models of elastomeric half-mask respirator (EHR), against sodium chloride particles (NaCl) in a range of 10 to 400 nm. Twenty-five human test subjects performed modified OSHA fit test exercises in...

متن کامل

Comparison of Simulated Workplace Protection Factors Offered by N 95 and P 100 Filtering Facepiece and Elastomeric Half - Mask Respirators

This study compared the simulated workplace protection factors (SWPFs) between NIOSH-approved N95 respirators and P100 respirators, including two models of filtering facepiece respirator (FFR) and two models of elastomeric halfmask respirator (EHR),against sodium chloride particles (NaCl) in a range of 10 to 400 nm. Twenty-five human test subjects performed modified OSHA fit test exercises in a...

متن کامل

Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles.

Protection of the human respiratory system from exposure to nanoparticles is becoming an emerging issue in occupational hygiene. The potential adverse health effects associated with particles of approximately 1-100 nm are probably greater than submicron or micron-sized particles. The performance of two models of N95 half-facepiece-filtering respirators against nano-sized particles was evaluated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 58 9  شماره 

صفحات  -

تاریخ انتشار 2014