Intra- and inter-rater reliability of jumping mechanography muscle function assessments.
نویسندگان
چکیده
Muscle function can be assessed through jumping mechanography, where portable ground reaction force plates collect dynamic information as a subject jumps. The aim of this study was to assess both intra- and inter- rater reliability of jumping mechanography. Ten healthy adults underwent 3 sets of testing (collected by 3 different raters) at two separate sessions, one week apart. They performed a number of tests in each session: multiple one-legged hopping (M1LH; on right and left legs) and single two-legged jumps (S2LJ; with or without arm swing). The S2LJ assessed variables of power per body mass, jump height, velocity and efficiency; whereas, M1LH assessed maximum force per body mass and stiffness. Inter-rater coefficients of variation (CV) were less than 0.6% and 2.6% for the S2LJ and M1LH, respectively, for the primary outcome variables of power/body mass and force/body mass. Analyzing intra-rater results also produced CVs less than 5.3% for all variables. The present study reports that the Leonardo ground reaction force plate system yields reproducible results between sessions, without significant contribution of variability from the test operator. Jumping mechanography is an easy, safe and reliable method for the assessment of lower limb musculoskeletal function.
منابع مشابه
Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy
Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...
متن کاملEvaluation of Spasticity Using the Ashworth Scale with Intermediate Scores (ASIS)
Objectives: The main purpose of this research was to study and contribute to an accurate test of spastic limb. The intra, inter rater reliability of the test was examined. Methods: The present study was carried out in two parts In the first part of the study, the modified Ashworth Scale with Intermediate Scores (ASIS) was studied. During the second part of the study the intra, inter rater re...
متن کاملReliability of pelvic floor muscle strength assessment in healthy continent women
BACKGROUND The aim of this study was to compare pelvic floor muscle (PFM) strength using transvaginal digital palpation in healthy continent women in different age groups, and to compare the inter- and intra-rater reliability of examiners performing anterior and posterior vaginal assessments. METHODS We prospectively studied 150 healthy multiparous women. They were distributed into four diffe...
متن کاملIntra and inter-rater reliability of infrared image analysis of masticatory and upper trapezius muscles in women with and without temporomandibular disorder.
BACKGROUND Infrared thermography is an aid tool that can be used to evaluate several pathologies given its efficiency in analyzing the distribution of skin surface temperature. OBJECTIVES To propose two forms of infrared image analysis of the masticatory and upper trapezius muscles, and to determine the intra and inter-rater reliability of both forms of analysis. METHOD Infrared images of m...
متن کاملIntra- and inter-rater reliability of maximum inspiratory pressure measured using a portable capsule-sensing pressure gauge device in healthy adults
BACKGROUND Measurement of maximum inspiratory pressure is the most prevalent method used in clinical practice to assess the strength of the inspiratory muscles. Although there are many devices available for the assessment of inspiratory muscle strength, there is a dearth of literature describing the reliability of devices that can be used in clinical patient assessment. The capsule-sensing pres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of musculoskeletal & neuronal interactions
دوره 13 4 شماره
صفحات -
تاریخ انتشار 2013